منزل المنتجاتأدوات Endress Hauser

24V DC Endress Hauser Promass F 300 Coriolis Flowmeter DN 8-250

ابن دردش الآن

24V DC Endress Hauser Promass F 300 Coriolis Flowmeter DN 8-250

24V DC Endress Hauser Promass F 300 Coriolis Flowmeter DN 8-250
24V DC Endress Hauser Promass F 300 Coriolis Flowmeter DN 8-250 24V DC Endress Hauser Promass F 300 Coriolis Flowmeter DN 8-250 24V DC Endress Hauser Promass F 300 Coriolis Flowmeter DN 8-250

صورة كبيرة :  24V DC Endress Hauser Promass F 300 Coriolis Flowmeter DN 8-250

تفاصيل المنتج:
مكان المنشأ: ألمانيا
اسم العلامة التجارية: Endress+Hauser
إصدار الشهادات: CE
Model Number: 8F3B40-BSIBABEFAASAFMWAA2( 8F3B40-1VKX5/0)
شروط الدفع والشحن:
الحد الأدنى لكمية: 1 قطعة
الأسعار: قابل للتفاوض
تفاصيل التغليف: تعبئة الكرتون القياسية
وقت التسليم: عند الطلب
شروط الدفع: تي/تي
القدرة على العرض: 100pcs في الشهر
اتصل تحدث الآن

24V DC Endress Hauser Promass F 300 Coriolis Flowmeter DN 8-250

وصف
Nominal diameter range: DN 8 to 250 (⅜ to 10") الأعلى. عملية الضغط: PN 100 ، الفئة 600 ، 63K
Sensor housing material: Standard: 1.4301 (304) Option: 1.4404 (316/316L) المدخلات: إدخال الحالة 4-20 مللي أمبير إدخال
مزود الطاقة: DC 24 V AC 100 إلى 230 V AC 100 to 230 V / DC 24 V (منطقة غير خطرة) سلامة المنتج: CE ، C-Tick ، ​​وضع علامة EAC
إبراز:

Endress Hauser Promass F 300 Coriolis,F 300 Coriolis Flowmeter,24V DC proline promass f 300 coriolis flowmeter

,

F 300 Coriolis Flowmeter

,

24V DC proline promass f 300 coriolis flowmeter

Endress+Hauser Proline Promass F 300 Coriolis Flowmeter 8F3B40 with DC 24 V Power Supply
Product Attributes
Attribute Value
Nominal diameter range DN 8 to 250 (⅜ to 10")
Max. process pressure PN 100, Class 600, 63K
Sensor housing material Standard: 1.4301 (304) Option: 1.4404 (316/316L)
Inputs Status input 4-20 mA input
Power supply DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area)
Product safety CE, C-tick, EAC marking
Product Description

The Endress+Hauser Proline Promass F 300 Coriolis flowmeter 8F3B40 has a long-standing reputation as a highly accurate sensor. Immune to fluctuating and harsh environments, it is suited for the broadest range of applications. With its compact transmitter, the Promass F 300 offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

The measuring principle operates independently of physical fluid properties such as viscosity or density, providing highest measurement performance for liquids and gases under varying, demanding process conditions.

Device Properties
  • Mass flow: measurement error ±0.05% (PremiumCal)
  • Medium temperature: -196 to 350°C (-320 to 662°F)
  • Nominal diameter: DN 8 to 250 (³⁄₈ to 10")
  • Compact dual-compartment housing with up to 3 I/Os
  • Backlit display with touch control and WLAN access
  • Remote display available
Related Models
24V DC Endress Hauser Promass F 300 Coriolis Flowmeter DN 8-250 0
24V DC Endress Hauser Promass F 300 Coriolis Flowmeter DN 8-250 1

تفاصيل الاتصال
SC Automation Limited

اتصل شخص: Ms. Joy chen

الهاتف :: +8615012673027

الفاكس: 86--15012673027

إرسال استفسارك مباشرة لنا (0 / 3000)

منتجات أخرى