Rumah ProdukPemancar Yokogawa

YOKOGAWA EJA118E DP Transmitter with HART 7 Protocol

I 'm Online Chat Now

YOKOGAWA EJA118E DP Transmitter with HART 7 Protocol

YOKOGAWA EJA118E DP Transmitter with HART 7 Protocol
YOKOGAWA EJA118E DP Transmitter with HART 7 Protocol YOKOGAWA EJA118E DP Transmitter with HART 7 Protocol

Gambar besar :  YOKOGAWA EJA118E DP Transmitter with HART 7 Protocol

Detail produk:
Tempat asal: Yokogawa
Nama merek: YOKOGAWA
Sertifikasi: CE
Nomor model: EJA118E-JMSCJ-912NB-WA13A1SW00-AA25/D4
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1 buah
Harga: Bisa dinegosiasikan
Kemasan rincian: Pengepakan karton standar
Waktu pengiriman: berdasarkan permintaan
Syarat-syarat pembayaran: T/T
Menyediakan kemampuan: 100 pcs per bulan
Kontak Chat Sekarang

YOKOGAWA EJA118E DP Transmitter with HART 7 Protocol

Deskripsi
Sinyal keluaran: 4 hingga 20 mA DC dengan komunikasi digital (protokol HART 5/HART 7) Jangkauan pengukuran (kapsul): 2,5 hingga 100 kPa (10 hingga 400 inH2O)
Bahan penutup flensa baut dan mur: Baja karbon B7 Instalasi: Tipe perpipaan horizontal dan tekanan tinggi sisi kiri
Rumah penguat: Alloy Aluminium Tiris Sambungan Listrik: 1/2 NPT betina, dua sambungan listrik tanpa colokan buta
Braket pemasangan: Pemasangan pipa 304 SST 2 inci, tipe datar (untuk perpipaan horizontal) Gaya koneksi proses: Bagian badan pemancar
Menyoroti:

CE eja118e yokogawa

,

1/2 NPT eja118e yokogawa

,

DP Transmitter

CE EJA118E YOKOGAWA DP Transmitter EJA118E-JMSCJ-912NB-WA13A1SW00-AA25/D4
Product Specifications
Attribute Value
Output signal 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)
Measurement span (capsule) 2.5 to 100 kPa (10 to 400 inH2O)
Coverflange bolts and nuts material B7 carbon steel
Installation Horizontal piping type and left side high pressure
Amplifier housing Cast aluminum alloy
Electrical connection 1/2 NPT female, two electrical connections without blind plugs
Mounting bracket 304 SST 2-inch pipe mounting, flat type (for horizontal piping)
Process connection style Transmitter body section
Product Description

YOKOGAWA EJA118E DP Transmitter with Remote Diaphragm Seals EJA118E-JMSCJ-912NB-WA13A1SW00-AA25/D4

The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.

The EJA118E is a Differential Pressure Transmitter with remote diaphragm seals.

Key Features
  • ± 0.2% Accuracy
  • 200 ms Response Time
  • Exida and TUV SIL2 / SIL3 Certified
  • Local Parameter Setting (LPS)
  • 10-segment Signal Characterizer
  • Active Capillary Fill Fluid Density Compensation
YOKOGAWA EJA118E DP Transmitter with HART 7 Protocol 0
EJA118E Process Connections
Process Connection Type Size Extension Flange
YOKOGAWA EJA118E DP Transmitter with HART 7 Protocol 1 Flush Type Flush Type 3-inch
2-inch
1-½-inch
N/A JIS 10K, 20K, 30K
ANSI 100#, 300#, 600#
JPI Class 150, 300, 600
DIN PN10/16, 25/40, 64
YOKOGAWA EJA118E DP Transmitter with HART 7 Protocol 2 Extended Type Extended Type 4-inch
3-inch
2-inch
4-inch
6-inch
JIS 10K, 20K
ANSI 150#, 300#
JPI Class 150, 300
DIN PN10/16, 25/40
YOKOGAWA EJA118E DP Transmitter with HART 7 Protocol 3 Extended Type Flush Type Low-Pressure Side: 3-inch
High-Pressure Side: 4-inch
Low-Pressure Side: N/A
High-Pressure Side: 2-inch
4-inch
6-inch
JIS 10K, 20K
ANSI 150#, 300#
JPI Class 150, 300
DIN PN10/16, 25/40
Related Part Numbers
EJA118E-JMSCJ-912NB-WA13A1SW00-AA25/D4
EJA118E-JMSCC-910DB-WA13B2SW00-AA24/TF1
EJA118E-JMSCG-919EJ-WD23C2HW00-BA23/KU22/X2/N4
EJA118E-JMSCG-919EJ-WD23C2SW00-BA23/KU22/X2/N4
EJA118E-JMSCG-919EJ-WD23C2SW00-BA2A/KU22/X2/N4
EJA118E-FMSCG-919DB-WA43C1SW00-2A24/X2/M2W/T58
EJA118E-FMSCG-919DB-WA13C1SW00-1A2A/X2/M2W/T52
EJA118E-FHSCJ-914DB-WA12B1SW00-AA2A/KS26/D3/M2W
EJA118E-JMSCJ-919DB-WA42C2SW00-AA23/KS21/D3
EJA118E-JMSCJ-919DB-WA22C2SW00-AA27/KS21/D3
EJA118E-JMSCG-919DB-WA22C1SW00-BA26/KS21/M2W
EJA118E-FHSCG-919DN-WA23C2SW00-BA2A/KS26/T56
EJA118E-JMSCG-92DDJ-WA23C2TW00-AA25/KS21/A/D4/M2W/T56
EJA118E-JMSCG-93DDB-WA12C1SW00-BA24/KU22/D4/M2W/T52
EJA118E-JMSCG-93DDB-WA12C1SW00-EA24/KU22/D4/M2W/T52
EJA118E-JMSCG-924DB-WA23C2SW00-AA25/KS21/D4/M2W/T56
EJA118E-FMSCJ-914DB-WA22B1SW00-AA25/KS26/D4/M2W
EJA118E-FMSCG-919DB-WA23C1SW00-AA25/X2/D4/T56/M2W
EJA118E-JMSCG-919DB-WA12C1SW00-AA25/X2/D4/M2W/T52/KU22
YOKOGAWA EJA118E DP Transmitter with HART 7 Protocol 4

Rincian kontak
SC Automation Limited

Kontak Person: Ms. Joy chen

Tel: +8615012673027

Faks: 86--15012673027

Mengirimkan permintaan Anda secara langsung kepada kami (0 / 3000)

Produk lainnya