Nhà Sản phẩmMtl rào cản an toàn

MTL5544D 24V Repeater Power Supply for HART Transmitters

Tôi trò chuyện trực tuyến bây giờ

MTL5544D 24V Repeater Power Supply for HART Transmitters

MTL5544D 24V Repeater Power Supply for HART Transmitters
MTL5544D 24V Repeater Power Supply for HART Transmitters MTL5544D 24V Repeater Power Supply for HART Transmitters MTL5544D 24V Repeater Power Supply for HART Transmitters MTL5544D 24V Repeater Power Supply for HART Transmitters MTL5544D 24V Repeater Power Supply for HART Transmitters

Hình ảnh lớn :  MTL5544D 24V Repeater Power Supply for HART Transmitters

Thông tin chi tiết sản phẩm:
Nguồn gốc: Hoa Kỳ
Hàng hiệu: MTL
Chứng nhận: CE
Số mô hình: MTL5544D
Thanh toán:
Số lượng đặt hàng tối thiểu: 1 mảnh
Giá bán: Có thể thương lượng
chi tiết đóng gói: Đóng gói carton tiêu chuẩn
Thời gian giao hàng: theo yêu cầu
Điều khoản thanh toán: T/T
Khả năng cung cấp: 100pc mỗi tháng
Tiếp xúc Chat ngay bây giờ

MTL5544D 24V Repeater Power Supply for HART Transmitters

Sự miêu tả
Số lượng kênh: Một Nhiệt độ trôi: < 0,8µA/°C
Thời gian phản hồi: Nằm trong phạm vi 10% của giá trị cuối cùng trong vòng 50μs Hỗ trợ truyền thông: HART (đầu cuối 1 & 2, chỉ đầu ra Ch 1)
Chỉ báo LED: Màu xanh lá cây: chỉ báo nguồn Phân hao năng lượng tối đa trong đơn vị: 96mA ở 24V dc
Làm nổi bật:

24V MTL Safety Barrier

,

96ma MTL5544D MTL Safety Barrier

,

CE REPEATER POWER SUPPLY

96ma 24v MTL Safety Barrier MTL5544D Repeater Power Supply
Key Attributes
Attribute Value
Number of channels One
Temperature drift < 0.8µA/°C
Response time Settles to within 10% of final value within 50µs
Communications supported HART (terminals 1 & 2, output Ch 1 only)
LED indicator Green: power indication
Maximum power dissipation within unit 96mA at 24V dc
Product Overview
MTL5544D REPEATER POWER SUPPLY

The MTLx544D provides a fully-floating dc supply for energising a conventional 2- or 3-wire 4/20mA transmitter located in a hazardous area, and repeats the current in other circuits to drive two safe-area loads. For HART 2-wire transmitters, the unit allows bi-directional transmission of digital communication signals superimposed on the 4/20mA loop current. Separately powered current sources, such as 4-wire transmitters, can be connected but will not support HART communication.

Technical Specifications
Number of channels: One
Location of transmitter: Zone 0, IIC, T4-6 hazardous area if suitably certified Div. 1, Group A hazardous location
Safe-area output: Signal range: 4 to 20mA Under/over-range: 0 to 24mA
Safe-area load resistance: @ 24mA: 0 to 360Ω @ 20mA: 0 to 450Ω
Safe-area circuit output resistance: > 1MΩ
Safe-area circuit ripple: < 50µA peak-to-peak
Hazardous-area input: Signal range: 0 to 24mA (including over-range) Transmitter voltage: 16.5V at 20mA
Transfer accuracy at 20°C: Better than 15µA
Temperature drift: < 0.8µA/°C
Response time: Settles to within 10% of final value within 50µs
Communications supported: HART (terminals 1 & 2, output Ch 1 only)
LED indicator: Green: power indication
Maximum current consumption (with 20mA signals): 96mA at 24V dc
Power dissipation within unit (with 20mA signals): 1.4W @ 24V dc
Safety Description

Terminals 2 to 1 and 3: Uo =28V Io =93mA Po =651mW Um = 253V rms or dc Terminals 1 to 3: Simple apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected without further certification into any IS loop with an open-circuit voltage <28V

Related Part Numbers
MTL5544D 24V Repeater Power Supply for HART Transmitters 0