পণ্যের বিবরণ:
যোগাযোগ
এখন চ্যাট করুন
|
| অপারেটিং দূরত্ব রেট করা: | 5 মিমি | সুরক্ষা অখণ্ডতা স্তর (এসআইএল): | এসআইএল ২ |
|---|---|---|---|
| মিশন টাইম (TM): | 20 ক | Standards: | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
| সামুদ্রিক অনুমোদন: | DNVGL TAA00001A5 | সংযোগের ধরন: | তারের |
| পরিবেষ্টিত তাপমাত্রা: | -২৫... ১০০ ডিগ্রি সেলসিয়াস (১৩... ২১২ ডিগ্রি ফারেনহাইট) | Degree of protection: | IP66 / IP68 |
| বিশেষভাবে তুলে ধরা: | P&F Sensors NJ5-18GK-N,NJ5-18GK-N Inductive Sensor,Inductive Sensor 5mm |
||
| Attribute | Value |
|---|---|
| Rated operating distance | 5 mm |
| Safety Integrity Level (SIL) | SIL 2 |
| Mission Time (TM) | 20 a |
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
| Marine approval | DNVGL TAA00001A5 |
| Connection type | cable |
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Degree of protection | IP66 / IP68 |
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 4.05 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Current consumption | Measuring plate not detected: min. 3 mA Measuring plate detected: ≤ 1 mA |
| Safety Integrity Level (SIL) | SIL 2 |
| MTTFd | 4566 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Standard conformity | NAMUR: EN 60947-5-6:2000, IEC 60947-5-6:1999 Standards: EN 60947-5-2:2007, EN 60947-5-2/A1:2012, IEC 60947-5-2:2007, IEC 60947-5-2 AMD 1:2012 |
| IECEx approval | Equipment protection level Gb: IECEx PTB 11.0037X Equipment protection level Da: IECEx PTB 11.0037X Equipment protection level Mb: IECEx PTB 11.0037X |
| ATEX approval | Equipment protection level Gb: PTB 00 ATEX 2048 X Equipment protection level Da: PTB 00 ATEX 2048 X |
| UL approval | cULus Listed, General Purpose |
| CCC approval | Hazardous Location: 2020322315002255 |
| NEPSI approval | NEPSI certificate: GYJ16.1393X |
| CML approval | on request |
| ANZEx | 18.3018X |
| KCC approval | Hazardous Location: 19-AV4BO-0227 |
| Marine approval | DNVGL TAA00001A5 |
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Connection type | cable |
| Housing material | PBT/PPS |
| Sensing face | PBT |
| Degree of protection | IP66 / IP68 |
| Cable | Cable diameter: 6 mm ± 0.2 mm Bending radius: > 10 x cable diameter Material: PVC Core cross section: 0.75 mm² Length: 2 m |
| Dimensions | Length: 39 mm Diameter: 18 mm |
Use in the hazardous area: see instruction manuals
ব্যক্তি যোগাযোগ: Ms. Joy chen
টেল: +8615012673027
ফ্যাক্স: 86--15012673027