होम उत्पादएमर्सन रोज़माउंट ट्रांसमीटर

Emerson Rosemount Transmitter 333 HART Tri Loop Signal Converter 333U

मैं अब ऑनलाइन चैट कर रहा हूँ

Emerson Rosemount Transmitter 333 HART Tri Loop Signal Converter 333U

Emerson Rosemount Transmitter 333 HART Tri Loop Signal Converter 333U
Emerson Rosemount Transmitter 333 HART Tri Loop Signal Converter 333U Emerson Rosemount Transmitter 333 HART Tri Loop Signal Converter 333U Emerson Rosemount Transmitter 333 HART Tri Loop Signal Converter 333U Emerson Rosemount Transmitter 333 HART Tri Loop Signal Converter 333U

बड़ी छवि :  Emerson Rosemount Transmitter 333 HART Tri Loop Signal Converter 333U

उत्पाद विवरण:
उत्पत्ति के प्लेस: थाईलैंड
ब्रांड नाम: Rosemount
प्रमाणन: CE
मॉडल संख्या: 333यू
भुगतान & नौवहन नियमों:
न्यूनतम आदेश मात्रा: 1पीसी
मूल्य: बातचीत योग्य
पैकेजिंग विवरण: मानक कार्टन पैकिंग
प्रसव के समय: अनुरोध पर
भुगतान शर्तें: टी/टी
आपूर्ति की क्षमता: प्रति माह 100pcs
संपर्क करें अभी चैट करें

Emerson Rosemount Transmitter 333 HART Tri Loop Signal Converter 333U

वर्णन
उत्पादन में संकेत: 3 अतिरिक्त एनालॉग सिग्नल परिवेश तापमान प्रभाव: ±0.15% अवधि
स्थिरता: 12 महीनों के लिए ±0.1% अवधि व्यापक: 50 से 104 डिग्री फ़ारेनहाइट (10 से 40 डिग्री सेल्सियस)
भंडारण: -40 से 158 डिग्री फ़ारेनहाइट (-40 से 70 डिग्री सेल्सियस) संदर्भ सटीकता: ±0.045% स्पैन
DIMENSIONS: 1.57 x 3.11 x 3.36 इंच (40 x 79 x 85.5 मिमी) वज़न: 0.27 पौंड (0.12 किग्रा)
प्रमुखता देना:

emerson rosemount transmitter 333 hart

,

333u emerson rosemount transmitter

,

333u rosemount 644 temperature transmitter

Emerson Rosemount Transmitter 333 HART® Tri-Loop™ Signal Converter
The Rosemount 333 HART Tri-Loop Signal Converter provides three additional analog outputs by converting a digital HART multivariable signal into three independent 4-20 mA analog process variables. This eliminates the need for additional transmitters and wiring. Available in high-alarm or low-alarm configurations, it features DIN rail mount options and electrically isolated analog output channels for flexible system integration.
Product Specifications
Attribute Value
Output Signal 3 additional analog signals
Ambient Temperature Effect ±0.15% of span
Stability ±0.1% of span for 12 months
Ambient Temperature Range 50 to 104 °F (10 to 40 °C)
Storage Temperature Range –40 to 158 °F (–40 to 70 °C)
Reference Accuracy ±0.045% of span
Dimensions 1.57 x 3.11 x 3.36 in. (40 x 79 x 85.5 mm)
Weight 0.27 lb (0.12 kg)
Model Configuration
Base Model
Code Description
333 HART® Tri-Loop™
Alarm Options
Code Description
U High alarm
D Low alarm
Configuration Options
Code Description
C2 Custom configuration (Configuration Data Sheet must be completed)
Dimensional Drawing
Emerson Rosemount Transmitter 333 HART Tri Loop Signal Converter 333U 0
Related Part Numbers
1056-01-22-38-AN
1056-01-25-38-AN
1056-02-20-38
1056-03-22-32-AN
1057-02-20-32-42
1066-CL-HT-73
1066-P-HT-73
3900-1-10
3900-02-103
3900-10-1
3900VP-01-10
4847B61G01
5081-P-HT-20-73
21501-08
23242-02
23294-00-99
23502-08
23554-00
23820-00
24091-00
24263
33521-00
33523-00
211001L1NAQ4
499ACL-01-54-VP
Emerson Rosemount Transmitter 333 HART Tri Loop Signal Converter 333U 1

सम्पर्क करने का विवरण
SC Automation Limited

व्यक्ति से संपर्क करें: Ms. Joy chen

दूरभाष: +8615012673027

फैक्स: 86--15012673027

हम करने के लिए सीधे अपनी जांच भेजें (0 / 3000)

अन्य उत्पादों