Detail produk:
Tempat asal: Jerman
Nama merek: P+F
Sertifikasi: PTB 00 ATEX 2081
Nomor model: KFA6-SR2-EX2.W
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1 buah
Harga: Bisa dinegosiasikan
Kemasan rincian: Pengepakan karton standar
Waktu pengiriman: berdasarkan permintaan
Syarat-syarat pembayaran: T/T
Menyediakan kemampuan: 100 pcs per bulan
Kontak Chat Sekarang

KFA6-SR2-Ex2.W Switch Amplifier SIL 2 P+F Sensors Digital Input

Deskripsi
Tipe sinyal: Input digital Koneksi Pasokan: terminal 14, 15
Level Integritas Keselamatan (SIL): SIL 2 Tingkat perlindungan: Standar IEC 60529:2001
Elemen tampilan: LED Kompatibilitas elektromagnetik: NE 21:2006
Suhu Sekitar: -20 ... 60 °C (-4 ... 140 °F) Ukuran: 20 x 119 x 115 mm (0,8 x 4,7 x 4,5 inci) (L x T x D), tipe rumah B2
Menyoroti:

KFA6-SR2-Ex2.W Switch Amplifier

,

SIL 2 P+F Sensors

,

KFA6-SR2-Ex2.W

IEC 60529:2001 P+F Sensors Switch Amplifier KFA6-SR2-Ex2.W
Key Specifications
Signal type Digital Input
Supply Connection terminals 14, 15
Safety Integrity Level (SIL) SIL 2
Degree of protection IEC 60529:2001
Display elements LEDs
Electromagnetic compatibility NE 21:2006
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D), housing type B2
Switch Amplifier KFA6-SR2-Ex2.W

2-channel isolated barrier with 230 V AC supply, designed for dry contact or NAMUR inputs with relay contact output. Features line fault detection (LFD) and reversible mode of operation.

  • Up to SIL 2 according to IEC/EN 61508 / IEC/EN 61511
  • Compact housing width: 20 mm
  • 2-channel configuration
  • Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz
  • Compatible with NAMUR sensors and volt-free contacts
  • 2 x relay (change-over contact) outputs
Technical Specifications
General
Signal type Digital Input
Safety Integrity Level (SIL) SIL 2
Supply
Connection terminals 14, 15
Rated voltage 207 ... 253 V AC, 45 ... 65 Hz
Power dissipation 1.2 W
Power consumption max. 1.3 W
Input
Connection side field side
Connection terminals 1+, 2+, 3-; 4+, 5+, 6-
Rated values acc. to EN 60947-5-6 (NAMUR)
Line fault detection breakage I ≤ 0.1 mA, short-circuit I > 6 mA
Output
Connection output I: terminals 7, 8, 9; output II: terminals 10, 11, 12
Contact loading 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
Mechanical life 107 switching cycles
Product Images
KFA6-SR2-Ex2.W Switch Amplifier SIL 2 P+F Sensors Digital Input 0
KFA6-SR2-Ex2.W Switch Amplifier SIL 2 P+F Sensors Digital Input 1
KFA6-SR2-Ex2.W Switch Amplifier SIL 2 P+F Sensors Digital Input 2
Related Models

Rincian kontak
SC Automation Limited

Kontak Person: Ms. Joy chen

Tel: +8615012673027

Faks: 86--15012673027

Mengirimkan permintaan Anda secara langsung kepada kami (0 / 3000)