| Model: | FVM | Rentang dan kinerja kalibrasi sensor: | Akurasi viskositas ±0,2 cP (rentang 0-10 cP) kemudian ±1% FS pada rentang terkalibrasi, batas viskos |
|---|---|---|---|
| Panjang batang: | 0 mm: tanpa ekstensi batang dan dengan keran standar | Bahan bagian yang dibasahi (termasuk sambungan proses): | Baja tahan karat 316L, gigi yang dipoles secara elektro |
| Proses koneksi: | DN50, PN16, EN 1092-1, Tipe B1 | Jenis kalibrasi sensor: | Aliran gratis |
| Opsi perumahan pemancar: | Integral, paduan aluminium | Opsi keluaran pemancar: | Pemancar integral, Saluran B = keluaran mA, Saluran A = mA + HART, Saluran C = Modbus/RS-485 |
| Menyoroti: | emerson viscosity meter dn50,316l coriolis meter emerson,316l emerson viscosity meter |
||
| Attribute | Value |
|---|---|
| Model | FVM |
| Sensor calibration range and performance | Viscosity accuracy ±0.2 cP (0-10 cP range) then ±1% of FS of calibrated range, viscosity limit 20,000 cP |
| Stem length | 0 mm: no stem extension and with standard spigot |
| Materials of wetted parts (including process connection) | 316L stainless steel, electro-polished tines |
| Process connections | DN50, PN16, EN 1092-1, Type B1 |
| Sensor calibration types | Free stream |
| Transmitter housing option | Integral, aluminum alloy |
| Transmitter outputs option | Integral transmitter, Channel B = mA Output, Channel A = mA + HART, Channel C = Modbus/RS-485 |
Micro Motion Fork Viscosity Meters are accurate multi-variable devices that measure liquid viscosity, density and temperature under demanding conditions. These meters use vibrating fork technology to provide reliable direct insertion measurement.
Integral HART® I/O direct input of external temperature and pressure measurements provide enhanced readings.
Supports Analog (4-20 mA), HART®, WirelessHART®, Modbus® RS-485 and FOUNDATION™ Fieldbus communications.
| 2002011 | CPVC flow-through tee, 1½-in. national pipe thread (NPT) process connection |
| 9200273 | Extension cable, 11-conduit, shielded, unprepped, per foot |
| 9210012 | Buffer solution, pH 4.01, 16oz. (473ml) |
| 9210013 | Buffer solution, pH 6.86, 16oz. (473ml) |
| 9210014 | Buffer solution, pH 9.18, 16oz. (473ml) |
| 00390-7101-0001 | Low flow panel |
| 11275-01 | Handrail mounting assembly |
| 12707-00 | Jet spray cleaner |
| 23242-02 | Mounting adapter, 1½-in. insertion, 1x¾in. |
| 23554-00 | General Purpose Cable Gland Kit For Model 56, 1056, 1066, 54e, XMT |