Product Details:
Contact Now
Chat Now
|
Model: | FVM | Sensor Calibration Range And Performance: | Viscosity Accuracy ±0.2 CP (0-10 CP Range) Then ±1% Of FS Of Calibrated Range, Viscosity Limit 20, 000 CP |
---|---|---|---|
Stem Length: | 0 Mm: No Stem Extension And With Standard Spigot | Materials Of Wetted Parts (including Process Connection): | 316L Stainless Steel, Electro-polished Tines |
Process Connections: | DN50, PN16, EN 1092-1, Type B1 | Sensor Calibration Types: | Free Stream |
Transmitter Housing Option: | Integral, Aluminum Alloy | Transmitter Outputs Option: | Integral Transmitter, Channel B = MA Output, Channel A = MA + HART, Channel C = Modbus/RS-485 |
Highlight: | emerson viscosity meter dn50,316l coriolis meter emerson,316l emerson viscosity meter |
Attribute | Value |
---|---|
Model | FVM |
Sensor calibration range and performance | Viscosity accuracy ±0.2 cP (0-10 cP range) then ±1% of FS of calibrated range, viscosity limit 20,000 cP |
Stem length | 0 mm: no stem extension and with standard spigot |
Materials of wetted parts (including process connection) | 316L stainless steel, electro-polished tines |
Process connections | DN50, PN16, EN 1092-1, Type B1 |
Sensor calibration types | Free stream |
Transmitter housing option | Integral, aluminum alloy |
Transmitter outputs option | Integral transmitter, Channel B = mA Output, Channel A = mA + HART, Channel C = Modbus/RS-485 |
Micro Motion Fork Viscosity Meters are accurate multi-variable devices that measure liquid viscosity, density and temperature under demanding conditions. These meters use vibrating fork technology to provide reliable direct insertion measurement.
Integral HART® I/O direct input of external temperature and pressure measurements provide enhanced readings.
Supports Analog (4-20 mA), HART®, WirelessHART®, Modbus® RS-485 and FOUNDATION™ Fieldbus communications.
2002011 | CPVC flow-through tee, 1½-in. national pipe thread (NPT) process connection |
9200273 | Extension cable, 11-conduit, shielded, unprepped, per foot |
9210012 | Buffer solution, pH 4.01, 16oz. (473ml) |
9210013 | Buffer solution, pH 6.86, 16oz. (473ml) |
9210014 | Buffer solution, pH 9.18, 16oz. (473ml) |
00390-7101-0001 | Low flow panel |
11275-01 | Handrail mounting assembly |
12707-00 | Jet spray cleaner |
23242-02 | Mounting adapter, 1½-in. insertion, 1x¾in. |
23554-00 | General Purpose Cable Gland Kit For Model 56, 1056, 1066, 54e, XMT |
Contact Person: Ms. Joy chen
Tel: +8615012673027
Fax: 86--15012673027