خانه محصولاتفرستنده امرسون رزماونت

Rosemount 5081-P Two Wire PH ORP Transmitter With HART Protocol

چت IM آنلاین در حال حاضر

Rosemount 5081-P Two Wire PH ORP Transmitter With HART Protocol

Rosemount 5081-P Two Wire PH ORP Transmitter With HART Protocol
Rosemount 5081-P Two Wire PH ORP Transmitter With HART Protocol Rosemount 5081-P Two Wire PH ORP Transmitter With HART Protocol Rosemount 5081-P Two Wire PH ORP Transmitter With HART Protocol

تصویر بزرگ :  Rosemount 5081-P Two Wire PH ORP Transmitter With HART Protocol

جزئیات محصول:
محل منبع: سنگاپور
نام تجاری: ROSEMOUNT
گواهی: CE
شماره مدل: 5081-P-HT-20-73
پرداخت:
مقدار حداقل تعداد سفارش: 1 پی سی
قیمت: قابل مذاکره
جزئیات بسته بندی: بسته بندی کارتن استاندارد
زمان تحویل: در صورت درخواست
شرایط پرداخت: T/T
قابلیت ارائه: 100 قطعه در هر ماه
مخاطب حالا صحبت کن

Rosemount 5081-P Two Wire PH ORP Transmitter With HART Protocol

شرح
محفظه: آلومینیوم ریخته گری با پوشش اپوکسی. نوع 4X (IP65). نئوپرن O-ring پوشش مهر و موم. ابعاد: 160.5 mm x 175.3 mm x 161.3 mm (6.3 x 6.9 x 6.4 اینچ) به طرح مراجعه کنید
دهانه های مجرا:: ¾ - در. FNPT دمای محیط: -4 تا 149 درجه فارنهایت (20- تا 65 درجه سانتی گراد)
دمای ذخیره سازی: -22 تا 176 درجه فارنهایت (30- تا 80 درجه سانتی گراد) رطوبت نسبی: 0 تا 95 ٪ (غیرقانونی)
وزن / وزن حمل و نقل: 10 پوند/10 پوند (4.5/5.0 کیلوگرم) نمایش: ال سی دی دو خط
برجسته کردن:

Rosemount 5081-P pH ORP Transmitter,Two Wire pH ORP Transmitter,HART Protocol pH ORP Transmitter

,

Two Wire pH ORP Transmitter

,

HART Protocol pH ORP Transmitter

1/4 FNPT Rosemount 5081-P Two Wire PH ORP Transmitter 5081-P-HT-20-73
Product Attributes
Housing Cast aluminum with epoxy coating. Type 4X (IP65). Neoprene O-ring cover seals.
Dimensions 160.5 mm x 175.3 mm x 161.3 mm (6.3 in. x 6.9 in. x 6.4 in.) See drawing
Conduit Openings ¾-in. FNPT
Ambient Temperature -4 to 149°F (-20 to 65°C)
Storage Temperature -22 to 176°F (-30 to 80°C)
Relative Humidity 0 to 95% (non-condensing)
Weight/Shipping weight 10 lb/10 lb (4.5/5.0 kg)
Display Two-line LCD
Product Description
The Rosemount Model 5081-P Two-Wire pH/ORP Transmitter (5081-P-HT-20-73) is designed for measuring pH or ORP in various process liquids. Compatible with most Rosemount Analytical sensors, this transmitter features a rugged, weatherproof enclosure with epoxy-painted aluminum construction that meets Type 4X and IP65 standards, along with explosion-proof certification.
The unit includes a two-line seven-segment display with 0.8-inch (20 mm) high numerals for the main measurement and 0.3-inch (7 mm) digits for secondary measurements (temperature and pH when measuring free chlorine). Available with HART (model option -HT) or Foundation Fieldbus (model option -FF) digital communication protocols, the transmitter supports AMS (Asset Management Solutions) for remote setup, configuration, process monitoring, and troubleshooting.
Replacement Parts for Model 5081-P pH/ORP Transmitter
PN Description Shipping weight
23992-02 For Model 5081-P-HT -- PCB stack consisting of the CPU, communication, and analog boards; display board is not included; CPU, communication, and analog boards are factory-calibrated as a unit and cannot be ordered separately 1 lb/0.5 kg
23992-03 For Model 5081-P-F -- PCB stack consisting of the CPU, communication, and analog boards; display board is not included; CPU, communication, and analog boards are factory-calibrated as a unit and cannot be ordered separately 1 lb/0.5 kg
23652-01 LCD display PCB 1 lb/0.5 kg
33337-02 Terminal block 1 lb/0.5 kg
23593-01 Enclosure cover, front with glass window 3 lb/1.5 kg
33360-00 Enclosure, center housing 4 lb/1.5 kg
33362-00 Enclosure cover, rear 3 lb/1.0 kg
9550187 O-ring (2-252), one, front and rear covers each require an O-ring 1 lb/0.5 kg
Screw, 8-32 x 0.5 inch, for attaching terminal block to center housing
Screw, 8-32 x 1.75 inch, for attaching circuit board stack to center housing
33342-00 Cover lock 1 lb/0.5 kg
33343-00 Locking bracket nut 1 lb/0.5 kg
Screw, 10-24 x 0.38 inch, for attaching cover lock and locking bracket nut to center housing