خانه محصولاتmtl موانع ایمنی

MTL5546 Zone 0 Isolating Driver For HART Communications Isolated Gate Driver

چت IM آنلاین در حال حاضر

MTL5546 Zone 0 Isolating Driver For HART Communications Isolated Gate Driver

MTL5546 Zone 0 Isolating Driver For HART Communications Isolated Gate Driver
MTL5546 Zone 0 Isolating Driver For HART Communications Isolated Gate Driver MTL5546 Zone 0 Isolating Driver For HART Communications Isolated Gate Driver MTL5546 Zone 0 Isolating Driver For HART Communications Isolated Gate Driver MTL5546 Zone 0 Isolating Driver For HART Communications Isolated Gate Driver MTL5546 Zone 0 Isolating Driver For HART Communications Isolated Gate Driver

تصویر بزرگ :  MTL5546 Zone 0 Isolating Driver For HART Communications Isolated Gate Driver

جزئیات محصول:
محل منبع: ایالات متحده آمریکا
نام تجاری: MTL
گواهی: CE
شماره مدل: MTL5546
پرداخت:
مقدار حداقل تعداد سفارش: 1 قطعه
قیمت: قابل مذاکره
جزئیات بسته بندی: بسته بندی کارتن استاندارد
زمان تحویل: در صورت درخواست
شرایط پرداخت: T/T
قابلیت ارائه: 100 قطعه در هر ماه
مخاطب حالا صحبت کن

MTL5546 Zone 0 Isolating Driver For HART Communications Isolated Gate Driver

شرح
تعداد کانال ها: یکی محل مبدل I/P: منطقه 0، IIC، منطقه خطرناک T4-6 در صورت تایید مناسب Div. 1، گروه A، مکان خطرناک
محدوده کاری: 4 تا 20 میلی آمپر حرکت دما: < 1.0μA/°C
ارتباطات پشتیبانی می شود: گودال نشانگر LED: سبز: نشانگر قدرت
برجسته کردن:

MTL5546 Zone 0 Isolating Driver,Zone 0 sic isolated gate driver,HART Communications isolated gate driver

,

Zone 0 sic isolated gate driver

,

HART Communications isolated gate driver

Zone 0 MTL5546 Isolating Driver SIC Isolated Gate Driver
Product Attributes
Attribute Value
Number of channels One
Location of I/P converter Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A, hazardous location
Working range 4 to 20mA
Temperature drift < 1.0µA/°C
Communications supported HART
LED indicator Green: power indication
Product Description

The MTLx546 accepts a 4/20mA floating signal from a safe-area controller to drive a current/pressure converter (or any other load up to 800Ω) in a hazardous area. For HART valve positioners, the module also permits bi-directional transmission of digital communication signals. Process controllers with a readback facility can detect open or short circuits in the field wiring: if these occur, the current taken into the terminals drops to a preset level.

The MTL4546C and the MTLx546Y are very similar to the MTLx546 except that they provide open circuit detection only (i.e. no short-circuit detection).

Specifications
  • Number of channels: One
  • Location of I/P converter: Zone 0, IIC, T4-6 hazardous area if suitably certified Div. 1, Group A, hazardous location
  • Working range: 4 to 20mA
  • Digital signal bandwidth: 500Hz to 10kHz
  • Maximum load resistance: 800Ω (16V at 20mA)
  • Minimum load resistance: 90Ω (short-circuit detection at < 50Ω)
  • Output resistance: > 1MΩ
  • Under/over range capability: Under range = 1mA, Over range = 24mA (load ≤ 520Ω)
  • Input and output circuit ripple: < 40µA peak-to-peak
  • Transfer accuracy at 20°C: Better than 20µA
  • Temperature drift: < 1.0µA/°C
  • Response time: Settles within 200µA of final value within 100ms
  • Communications supported: HART
  • LED indicator: Green: power indication
  • Maximum current consumption (with 20mA signals into 250Ω load): 35mA at 24V dc
  • Power dissipation within unit (with 20mA signals into 250Ω load): 0.8W at 24V
  • Safety description: Uo =28V Io =93mA Po =651mW Um = 253V rms or dc
Related Part Numbers
MTL5521
MTL4546Y
MTL7761PAC
MTL5522
MTL4549Y
MTL7765AC
MTL5531
MTL4573
MTL7787+
MTL5532
MTL4575
MTL7787P+
MTL5541
MTL4646Y
MTLCPS16
MTL5541S
MTL4850
NJ5-18GK-N
MTL5544
MTL4851
SD150X
MTL5544D
MTL4852
SD32
MTL5546
MTL5018
SD32X
MTL5546Y
MTL5032
SDRTD
MTL5561
MTL5042
SLP32D
MTL5573
MTL5044
TP48-3-I-NDI
MTL5575
MTL5049
TP48-3-N-NDI
MTL5582B
MTL5511
TP48-4-I-NDI
MTL7728+
MTL5514D
TP48-4-N-NDI
MTL7756AC
MTL5516
TP48-N-NDI
MTL7760AC
MTL5516C
ZB24571
MTL5546 Zone 0 Isolating Driver For HART Communications Isolated Gate Driver 0

اطلاعات تماس
SC Automation Limited

تماس با شخص: Ms. Joy chen

تلفن: +8615012673027

فکس: 86--15012673027

ارسال درخواست خود را به طور مستقیم به ما (0 / 3000)

سایر محصولات