Dom Produktybariera bezpieczeństwa mtl

MTL TP48-4-N-NDI Safety Barrier 20kA Surge Protection No Resistance

Im Online Czat teraz

MTL TP48-4-N-NDI Safety Barrier 20kA Surge Protection No Resistance

MTL TP48-4-N-NDI Safety Barrier 20kA Surge Protection No Resistance
MTL TP48-4-N-NDI Safety Barrier 20kA Surge Protection No Resistance MTL TP48-4-N-NDI Safety Barrier 20kA Surge Protection No Resistance MTL TP48-4-N-NDI Safety Barrier 20kA Surge Protection No Resistance MTL TP48-4-N-NDI Safety Barrier 20kA Surge Protection No Resistance

Duży Obraz :  MTL TP48-4-N-NDI Safety Barrier 20kA Surge Protection No Resistance

Szczegóły Produktu:
Miejsce pochodzenia: ANGLIA
Nazwa handlowa: MTL
Orzecznictwo: CE
Numer modelu: TP48-4-N-NDI
Zapłata:
Minimalne zamówienie: 1 szt
Cena: Zbywalny
Szczegóły pakowania: Standardowe pakowanie kartonu
Czas dostawy: na żądanie
Możliwość Supply: 100pcs miesięcznie
Kontakt Rozmawiaj teraz

MTL TP48-4-N-NDI Safety Barrier 20kA Surge Protection No Resistance

Opis
Maksymalny prąd udarowy: Prąd szczytowy 20 kA (kształt fali 8/20 µs) Prąd upływowy: Mniej niż 1µA przy maks. napięcie robocze
Napięcie robocze: maksymalnie 35V DC Przepustowość łącza: 1MHz
Opór: Do pętli nie wprowadzono żadnego oporu Waga: 175g. (6,2 uncji)
Podkreślić:

TP48-4-N-NDI MTL Safety Barrier

,

TP48-4-N-NDI Safety Barrier

,

MTL Isolated Safety Barrier

MTL Isolated Safety Barrier TP48-4-N-NDI With No Resistance
Product Specifications
Attribute Value
Maximum surge current 20kA peak current (8/20µs waveform)
Leakage current Less than 1µA at max. working voltage
Working voltage 35V dc maximum
Bandwidth 1MHz
Resistance No resistance introduced into loop
Weight 175g. (6.2oz.)
Product Overview
The MTL Isolated Safety Barrier TP48-4-N-NDI safeguards electronic process transmitters against induced surges and transients from field cabling.
Key Features
  • Protects 2, 3 and 4 wire transmitters
  • Easy and direct mounting - screws into spare conduit entry
  • Intrinsically safe and flameproof to CENELEC standards
  • Parallel connection avoids introduction of any resistance into loop
  • ATEX approved
  • 10 year product warranty
The TP48 range of surge protection devices uniquely provide a level of protection for 2, 3 and 4 wire field-mounted transmitters that is far in excess of the optional transient protection facilities available from the transmitter manufacturers - without involving any additional wiring, conduit modifications or other expensive extras.
The TP48 range protection network consists of high-power, solidstate electronics and a gas-filled discharge tube capable of diverting 20kA impulses. The whole unit is encased in a 316 stainless steel housing, threaded for the common conduit entries used on process transmitters. Versions are available for 1/2" NPT, 20mm ISO, and G1/2" (BSP 1/2 inch) threaded entries.
Ordering Information
Model Description Model Description
TP48-N Non-certified SPD - 1/2" NPT thread TP48-N-NDI Certified SPD - 1/2" NPT thread
TP48-I Non-certified SPD - 20mm ISO thread TP48-I-NDI Certified SPD - 20mm ISO thread
TP48-G Non-certified SPD - G 1/2" (BSP 1/2 inch) TP48-G-NDI Certified SPD - G 1/2" (BSP 1/2 inch)
TP48-3-N Non-certified SPD - 1/2" NPT thread TP48-3-N-NDI Certified SPD - 1/2" NPT thread
TP48-3-I Non-certified SPD - 20mm ISO thread TP48-3-I-NDI Certified SPD - 20mm ISO thread
TP48-3-G Non-certified SPD - G 1/2" BSP 1/2 inch TP48-3-G-NDI Certified SPD - 20mm ISO thread
TP48-4-N Non-certified SPD - 1/2" NPT thread TP48-4-N-NDI Certified SPD - 1/2" NPT thread
TP48-4-I Non-certified SPD - 20mm ISO thread TP48-4-I-NDI Certified SPD - 20mm ISO thread
TP48-4-G Non-certified SPD - G 1/2" BSP 1/2 inch TP48-4-G-NDI Certified SPD - G 1/2" - BSP 1/2 inch
MTL TP48-4-N-NDI Safety Barrier 20kA Surge Protection No Resistance 0 MTL TP48-4-N-NDI Safety Barrier 20kA Surge Protection No Resistance 1

Szczegóły kontaktu
SC Automation Limited

Osoba kontaktowa: Ms. Joy chen

Tel: +8615012673027

Faks: 86--15012673027

Wyślij zapytanie bezpośrednio do nas (0 / 3000)