Home ProductsEndress Hauser Instruments

Endress Hauser CYK10 Digital Measuring Cable 6.3mm Diameter Inductive Transmission

I'm Online Chat Now

Endress Hauser CYK10 Digital Measuring Cable 6.3mm Diameter Inductive Transmission

Endress Hauser CYK10 Digital Measuring Cable 6.3mm Diameter Inductive Transmission
Endress Hauser CYK10 Digital Measuring Cable 6.3mm Diameter Inductive Transmission Endress Hauser CYK10 Digital Measuring Cable 6.3mm Diameter Inductive Transmission Endress Hauser CYK10 Digital Measuring Cable 6.3mm Diameter Inductive Transmission Endress Hauser CYK10 Digital Measuring Cable 6.3mm Diameter Inductive Transmission Endress Hauser CYK10 Digital Measuring Cable 6.3mm Diameter Inductive Transmission

Large Image :  Endress Hauser CYK10 Digital Measuring Cable 6.3mm Diameter Inductive Transmission

Product Details:
Place of Origin: Germany
Brand Name: Endress+Hauser
Certification: ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Model Number: CYK10-A031 CYK10-A101 CYK10-A051 CYK10-A201 CYK10-E101
Payment & Shipping Terms:
Minimum Order Quantity: 1 piece
Price: negotiable
Packaging Details: standard carton packing
Delivery Time: on request
Payment Terms: T/T
Supply Ability: 100pcs per month
Contact Now Chat Now

Endress Hauser CYK10 Digital Measuring Cable 6.3mm Diameter Inductive Transmission

Description
Material: Cable Sheath: TPE Junction Box: Aluminum Dimension: Diameter: 6.3 Mm (0.25 Inch) Cores: 2x2 Cores, Twisted Pairs Length: Up To Approx. 100 M (328 Ft)
Measuring Principle: Potentiometric Application: Measuring Cable For Contactless, Inductive, Digital Transmission Of Measurement Signals
Characteristic: Inductive, Digital Transmission Of Measurement Signals And Energy Not Influenced By Moisture, EMC-fields And Corrosion Design: Easy To Handle Bajonett Coupling To Connect Digital Sensors With Memosens Technology And Plug-head No Open Contacts, Resistant Against Humidity
Process Temperature: -25 To 135 °C (-13 To 277 °F) Temperature Sensor: For Digital Sensors With Inductive Plug-head With And Without Temperature Sensor
Highlight:

6.3mm Endress Hauser Instruments

,

Endress Hauser Instruments CYK10-A201

,

CYK10-A031

Endress Hauser Instruments Digital Measuring Cable CYK10-A031 CYK10-A201 CYK10-E101
Product Specifications
Attribute Value
Material Cable sheath: TPE; Junction box: aluminum
Dimension Diameter: 6.3 mm (0.25 inch); Cores: 2x2 cores, twisted pairs; Length: up to approx. 100 m (328 ft)
Measuring principle Potentiometric
Application Measuring cable for contactless, inductive, digital transmission of measurement signals
Characteristic Inductive, digital transmission of measurement signals and energy; Not influenced by moisture, EMC-fields and corrosion
Design Easy to handle; Bajonett coupling to connect digital sensors with Memosens technology and plug-head; No open contacts, resistant against humidity
Process temperature -25 to 135 °C (-13 to 277 °F)
Temperature sensor For digital sensors with inductive plug-head with and without temperature sensor
Detailed Description
The Endress Hauser Digital Measuring Cable CYK10 series provides reliable, contactless signal transmission for industrial measurement applications. Available in multiple models including CYK10-A031, CYK10-A101, CYK10-A051, CYK10-A201, and CYK10-E101.
Key Features
  • Measuring principle: Potentiometric
  • Inductive, digital transmission of measurement signals and energy
  • Not influenced by moisture, EMC-fields or corrosion
  • Easy to handle with Bajonett coupling for Memosens technology
  • No open contacts, resistant against humidity
  • Process temperature range: -25 to 135 °C (-13 to 277 °F)
  • Process pressure: max. 50 bar/725 psi at 135°C/275°F
  • Ingress protection: IP68
  • Certifications: ATEX, FM, CSA, TÜV approved SIL version available
Field of Application
The CYK10 cable guarantees absolute water-proof connection of Memosens sensors to the transmitter. Its inductive coupling eliminates contact corrosion and provides galvanic isolation between transmitter and medium. The system overcomes limitations of cable length, interfering potentials, and moisture for completely safe and reliable signal transmission.
Applications include Memosens systems measuring:
  • pH/ORP
  • Dissolved oxygen (amperometric)
  • Conductive conductivity
  • Disinfection
Benefits
  • Maximum process safety through non-contact, inductive digital signal transmission
  • Eliminates contact corrosion and interference potential
  • Absolutely watertight design
  • Automatic error message if signal is lost
  • Flexible installation with cable lengths up to 100 m
  • Approved for hazardous area use
Related Part Numbers
FDU91-RG1AA FDU91-RG2AA COS61-A1F0 CUS71D-AA1A FMU42-APB2A22A FMU90-R11CA111AA3A FMU90-R11CA131AA3A COM253-WX0005 COS61D-AAA1A3 CPS11D-7BT2G FMU41-ARB2A2 FMU30-AAHEAAGGF CPS11D-7AA21 CPS71D-7TB21 CPS12D-7NA21 CPM223-PR0005 CUS52D-AA1AA3 FTL31-AA4U3BAWSJ CPS11D-7AS21 COS61-A2F0 CPS12D-7PA21 CPF81D-7LH11 CPS11D-7BA2G CPM253-PR0005 51518598 CM42-MEA000EAZ00 CUS51D-AAD1A3 CM442-AAM2A2F010A CM442-AAM1A2F011A+AK CYK10-G101 CYK10-G051 COY31-Z FMU30-AAHEABGHF COS61D-AAA1A4 CYK10-E051 CPS71D-7TB2G CLM253-CD0005 CM442-AAM1A2F010A FTW31-A2A5AA0A+1 L:600MM CPS31-1AC2ESA CPS31-1EC2ESA DK9CM-2 FTL41-AAA2AAAAA2CJAAAAJ L=1000MM CPS11-2AA2ESK FTM51-AGJ2L4A12AA L=2600MM PMP71-AAA2H21GAAAA CLM253-ID0005 COV45-41TN1 CPS11-2BA2ESA CPS77E-BA6BBU2 CLM223-CD0520 CPM253-MR8010
Endress Hauser CYK10 Digital Measuring Cable 6.3mm Diameter Inductive Transmission 0

Contact Details
SC Automation Limited

Contact Person: Ms. Joy chen

Tel: +8615012673027

Fax: 86--15012673027

Send your inquiry directly to us (0 / 3000)