منزل المنتجاتأدوات Endress Hauser

Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC

ابن دردش الآن

Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC

Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC
Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC

صورة كبيرة :  Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC

تفاصيل المنتج:
مكان المنشأ: ألمانيا
اسم العلامة التجارية: Endress+Hauser
إصدار الشهادات: CE
Model Number: FTE30-AAAB
شروط الدفع والشحن:
الحد الأدنى لكمية: 1 قطعة
الأسعار: قابل للتفاوض
تفاصيل التغليف: تعبئة الكرتون القياسية
وقت التسليم: 12-14 اسبوع
شروط الدفع: تي/تي
القدرة على العرض: 100pcs في الشهر
اتصل تحدث الآن

Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC

وصف
Power Supply; Output: 230VAC, relay 250VAC, 100mA -10A Process Connection: G1-1/2 male thread, PBT
Version: Shaft 100mm Paddle; Additional Option: 303; signal lamp; non-hazardous
Net weight: 0.950 Kilogram بلد المنشأ: دي
إبراز:

endress hauser fte30 soliswitch,rotary paddle level switch 230VAC,230VAC soliswitch fte30

,

rotary paddle level switch 230VAC

,

230VAC soliswitch fte30

Endress+Hauser Point Level Switch Soliswitch FTE30 Rotary Paddle Switch
Product Specifications
Attribute Value
Power Supply; Output 230VAC, relay 250VAC, 100mA -10A
Process Connection G1-1/2 male thread, PBT
Version Shaft 100mm
Paddle; Additional Option 303; signal lamp; non-hazardous
Net weight 0.950 Kilogram
Country of origin DE
Product Description

The economical Soliswitch FTE30 is a paddle switch for point level detection in bulk materials. Its robust polymer housing and compact design makes it an ideal sensor for full, empty and demand alarm in applications with bulk solids. The optimized materials make the unit outstandingly robust and therefore suitable for use in dust explosive areas.

  • Process connections: G 1½", PBT; G 1½", 1.4305; Reinforced shaft G 1½", 1.4305
  • Sensor length: Different standard lengths between 100 mm (4") and 600 mm (24"), additional rope length of 2,000 mm (80") (can be shortened)
  • Temperature: -20 to +80 °C (-4 to +170 °F)
  • Pressure: 0.5 to 1.8 bar (7 to 25 psi)
Technical Specifications
Measuring principle Paddle
Specialities Hinged paddle
Supply / Communication 230 VAC 50/60 Hz
115 VAC 50/60 Hz
48 VAC 50/60 Hz
24 VAC 50/60 Hz
20 bis 28 VDC
Ambient temperature -20 °C ... 60 °C (-4 °F ... 140 °F)
Process temperature -20 °C ... 80 °C (-4 °F ... 170 °F)
Process pressure / max. overpressure limit 0.5 bar to 1.5 bar (7 psi to 22 psi)
Min. density of medium >= 100 g/l
Main wetted parts Shaft: 1.4305
Paddle: 1.4301
Process connection G 1 1/2", PBT
G 1 1/2", 1.4305
Reinforced shaft G 1 1/2", 1.4305
Sensor length 100 mm (4")
200 mm (8")
300 mm (12")
400 mm (16")
500 mm (20")
600 mm (24")
Rope length of approx 2000 mm (80"), can be shortened
Communication Micro switch with changeover contact max. 10 A/250 VAC
Certificates / Approvals No approvals available
Options Relay
Application limits max. grain size 50 mm (2")
Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC 0

تفاصيل الاتصال
SC Automation Limited

اتصل شخص: Ms. Joy chen

الهاتف :: +8615012673027

الفاكس: 86--15012673027

إرسال استفسارك مباشرة لنا (0 / 3000)

منتجات أخرى