خانه محصولاتابزار Endress Hauser

Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC

چت IM آنلاین در حال حاضر

Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC

Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC
Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC

تصویر بزرگ :  Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC

جزئیات محصول:
محل منبع: آلمان
نام تجاری: Endress+Hauser
گواهی: CE
Model Number: FTE30-AAAB
پرداخت:
مقدار حداقل تعداد سفارش: 1 پی سی
قیمت: قابل مذاکره
جزئیات بسته بندی: بسته بندی کارتن استاندارد
زمان تحویل: 12-14 هفته
شرایط پرداخت: T/T
قابلیت ارائه: 100 قطعه در هر ماه
مخاطب حالا صحبت کن

Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC

شرح
Power Supply; Output: 230VAC, relay 250VAC, 100mA -10A Process Connection: G1-1/2 male thread, PBT
Version: Shaft 100mm Paddle; Additional Option: 303; signal lamp; non-hazardous
Net weight: 0.950 Kilogram کشور مبداء: حرف
برجسته کردن:

endress hauser fte30 soliswitch,rotary paddle level switch 230VAC,230VAC soliswitch fte30

,

rotary paddle level switch 230VAC

,

230VAC soliswitch fte30

Endress+Hauser Point Level Switch Soliswitch FTE30 Rotary Paddle Switch
Product Specifications
Attribute Value
Power Supply; Output 230VAC, relay 250VAC, 100mA -10A
Process Connection G1-1/2 male thread, PBT
Version Shaft 100mm
Paddle; Additional Option 303; signal lamp; non-hazardous
Net weight 0.950 Kilogram
Country of origin DE
Product Description

The economical Soliswitch FTE30 is a paddle switch for point level detection in bulk materials. Its robust polymer housing and compact design makes it an ideal sensor for full, empty and demand alarm in applications with bulk solids. The optimized materials make the unit outstandingly robust and therefore suitable for use in dust explosive areas.

  • Process connections: G 1½", PBT; G 1½", 1.4305; Reinforced shaft G 1½", 1.4305
  • Sensor length: Different standard lengths between 100 mm (4") and 600 mm (24"), additional rope length of 2,000 mm (80") (can be shortened)
  • Temperature: -20 to +80 °C (-4 to +170 °F)
  • Pressure: 0.5 to 1.8 bar (7 to 25 psi)
Technical Specifications
Measuring principle Paddle
Specialities Hinged paddle
Supply / Communication 230 VAC 50/60 Hz
115 VAC 50/60 Hz
48 VAC 50/60 Hz
24 VAC 50/60 Hz
20 bis 28 VDC
Ambient temperature -20 °C ... 60 °C (-4 °F ... 140 °F)
Process temperature -20 °C ... 80 °C (-4 °F ... 170 °F)
Process pressure / max. overpressure limit 0.5 bar to 1.5 bar (7 psi to 22 psi)
Min. density of medium >= 100 g/l
Main wetted parts Shaft: 1.4305
Paddle: 1.4301
Process connection G 1 1/2", PBT
G 1 1/2", 1.4305
Reinforced shaft G 1 1/2", 1.4305
Sensor length 100 mm (4")
200 mm (8")
300 mm (12")
400 mm (16")
500 mm (20")
600 mm (24")
Rope length of approx 2000 mm (80"), can be shortened
Communication Micro switch with changeover contact max. 10 A/250 VAC
Certificates / Approvals No approvals available
Options Relay
Application limits max. grain size 50 mm (2")
Endress Hauser Fte30 Soliswitch Rotary Paddle Level Switch 230VAC 0

اطلاعات تماس
SC Automation Limited

تماس با شخص: Ms. Joy chen

تلفن: +8615012673027

فکس: 86--15012673027

ارسال درخواست خود را به طور مستقیم به ما (0 / 3000)

سایر محصولات