Endress+Hauser Liquipoint FTW33 Capacitance Level Sensor with Hygienic Certificates Conductive Foam Detection and CIP/SIP Suitable

Informations de base
Nom de marque: Endress+Hauser
Documents: FTW33.pdf
Quantité de commande min: FTW33-1RT4/0
Prix: Négociable
Détails d'emballage: emballage d'origine
Délai de livraison: 8-12 semaines
Conditions de paiement: T/T
Capacité d'approvisionnement: 100 pièces par mois
Principe de mesure: Conducteur Tension d'alimentation: 10…30 V CC
Température ambiante: -40 ... 70°C (-40 ... 158°F) Température du processus: -20 ... 100°C (-4 ... 212°F)
Transformation de la pression: 0 à 25 bars abs (0 à 362,5 psi abs) Pièces mouillées: Capteur : 316L, Isolation du capteur : PEEK

Endress+Hauser Liquipoint FTW33 Capacitance Level Sensor
Product Overview

The Liquipoint FTW33 is developed for the food industry and meets all international hygiene requirements. The device also fits perfectly for applications in all industries.

Designed for use in pasty and sticky media and media with heavy build-up. Suitable for pipes and in storage, mixing and process vessels with or without an agitator.

Field of Application
  • For liquids with electrical conductivity >1 μS/cm or dielectric constant >2
  • Developed for the food industry
  • Detection of foam occurring within the food industry possible
  • Process connections: Threads and hygiene connections
  • Sensor length: Flush-mounted
Temperature Range -20 to +100°C (-4 to +212°F), CIP/SIP to 150°C (302°F) for 1 hour
Pressure Range 0 to 25 bar abs (0 to 362.5 psi abs)
Hygienic Certificates Included
Technical Specifications
Measuring Principle Conductive
Characteristic / Application Compact point level switch for using in pipes and in storage, mixing and process vessels with or without an agitator, for water based or oil based media, with active build up compensation, flush mounting
Specialities CIP and SIP suitable
Conductive foam is detectable or can be switched off
Supply / Communication 10…30 V DC
Ambient Temperature -40 ... 70°C (-40 ... 158°F)
Process Temperature Standard: -20 ... 100°C
Cleaning: -20 ... 150°C for 1h (-4 ... 302°F for 1h)
Process Pressure / Max. Overpressure Limit Vacuum ... 25 bar (Vacuum ... 362.5 psi)
Main Wetted Parts Sensor: 316L
Sensor isolation: PEEK
Process Connection Thread G1, G1/2, G3/4, M24
Process Connection Hygienic Clamp ISO 2852 1 to 1 1/2", 2", DIN11851 Pipe union
Communication DC PNP
Certifications & Approvals
Certificates / Approvals CSA C/US
Design Approvals EN 10204-3.1
Hygienic Approvals 3A, EHEDG
Options
  • Weld-in adapter
  • Process adapter for hygienic process connections
Product Images
Endress+Hauser Liquipoint FTW33 Capacitance Level Sensor with Hygienic Certificates Conductive Foam Detection and CIP/SIP Suitable 0 Endress+Hauser Liquipoint FTW33 Capacitance Level Sensor with Hygienic Certificates Conductive Foam Detection and CIP/SIP Suitable 1

Coordonnées
JOY

Je suis désolé. : +8613715021826