होम उत्पादएमटीएल सुरक्षा बाधा

MTL4546Y Isolating Driver 500Hz-10kHz 16V 20mA Hazardous Area

मैं अब ऑनलाइन चैट कर रहा हूँ

MTL4546Y Isolating Driver 500Hz-10kHz 16V 20mA Hazardous Area

MTL4546Y Isolating Driver 500Hz-10kHz 16V 20mA Hazardous Area
MTL4546Y Isolating Driver 500Hz-10kHz 16V 20mA Hazardous Area MTL4546Y Isolating Driver 500Hz-10kHz 16V 20mA Hazardous Area MTL4546Y Isolating Driver 500Hz-10kHz 16V 20mA Hazardous Area MTL4546Y Isolating Driver 500Hz-10kHz 16V 20mA Hazardous Area MTL4546Y Isolating Driver 500Hz-10kHz 16V 20mA Hazardous Area

बड़ी छवि :  MTL4546Y Isolating Driver 500Hz-10kHz 16V 20mA Hazardous Area

उत्पाद विवरण:
उत्पत्ति के प्लेस: यूएसए
ब्रांड नाम: MTL
प्रमाणन: CE
मॉडल संख्या: एमटीएल4546वाई
भुगतान & नौवहन नियमों:
न्यूनतम आदेश मात्रा: 1 टुकड़ा
मूल्य: बातचीत योग्य
पैकेजिंग विवरण: मानक कार्टन पैकिंग
प्रसव के समय: अनुरोध पर
भुगतान शर्तें: टी/टी
आपूर्ति की क्षमता: प्रति माह 100pcs
संपर्क करें अभी चैट करें

MTL4546Y Isolating Driver 500Hz-10kHz 16V 20mA Hazardous Area

वर्णन
चैनलों की संख्या: एक I/P कनवर्टर का स्थान: जोन 0, आईआईसी, टी4-6 खतरनाक क्षेत्र यदि उपयुक्त रूप से प्रमाणित हो। 1, समूह ए, खतरनाक स्थान
डिजिटल सिग्नल बैंडविड्थ: 500Hz से 10kHz अधिकतम भार प्रतिरोध: 800Ω (20mA पर 16V)
आउटपुट प्रतिरोध: > 1MΩ एलईडी सूचक: हरा: शक्ति संकेत
प्रमुखता देना:

MTL4546Y

,

10kHz isolating driver

,

500Hz isolating driver

500Hz To 10kHz MTL4546Y Isolating Driver 16V 20mA ODM
Product Attributes
Number of channels one
Location of I/P converter Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A, hazardous location
Digital signal bandwidth 500Hz to 10kHz
Maximum load resistance 800Ω (16V at 20mA)
Output resistance > 1MΩ
LED indicator Green: power indication
Product Description
MTL4546Y ISOLATING DRIVER

The MTLx546 accepts a 4/20mA floating signal from a safe-area controller to drive a current/pressure converter (or any other load up to 800Ω) in a hazardous area. For HART valve positioners, the module also permits bi-directional transmission of digital communication signals. Process controllers with a readback facility can detect open or short circuits in the field wiring: if these occur, the current taken into the terminals drops to a preset level. The MTL4546C and the MTLx546Y are very similar to the MTLx546 except that they provide open circuit detection only (i.e. no short-circuit detection).

Specifications
Number of channels: One
Location of I/P converter: Zone 0, IIC, T4-6 hazardous area if suitably certified Div. 1, Group A, hazardous location
Working range: 4 to 20mA
Digital signal bandwidth: 500Hz to 10kHz
Maximum load resistance: 800Ω (16V at 20mA)
Minimum load resistance: 90Ω (short-circuit detection at < 50Ω)
Output resistance: > 1MΩ
Under/over range capability: Under range = 1mA, Over range = 24mA (load ≤ 520Ω)
Input and output circuit ripple: < 40µA peak-to-peak
Transfer accuracy at 20°C: Better than 20µA
Temperature drift: < 1.0µA/°C
LED indicator: Green: power indication
Maximum current consumption: 35mA at 24V dc (with 20mA signals into 250Ω load)
Power dissipation within unit: 0.8W at 24V (with 20mA signals into 250Ω load)
Safety description: Uo =28V Io =93mA Po =651mW Um = 253V rms or dc