Rumah ProdukPemancar Emerson Rosemount

Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3

I 'm Online Chat Now

Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3

Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3
Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3 Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3 Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3

Gambar besar :  Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3

Detail produk:
Tempat asal: Meksiko
Nama merek: Rosemount
Sertifikasi: CE
Nomor model: 1066-P-HT-73
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1 buah
Harga: Bisa dinegosiasikan
Kemasan rincian: Pengepakan karton standar
Waktu pengiriman: berdasarkan permintaan
Syarat-syarat pembayaran: T/T
Menyediakan kemampuan: 100 pcs per bulan
Kontak Chat Sekarang

Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3

Deskripsi
Catu Daya: Tegangan suplai pada terminal pemancar harus minimal 12,7Vdc. Tegangan catu daya harus menutupi penu Protokol komunikasi: HART™ Komunikasi & diagnostik: PV, SV, TV, dan 4V yang dapat dialihkan, suhu
Diagnostik: PV, SV, TV, dan 4V dapat ditugaskan Masukan: Satu masukan sensor
Jenis pengukuran: Mengukur tingkat pH, tingkat konduktivitas, konsentrasi klorin, konsentrasi oksigen terlarut, dan ko Berat: R2 pon/3 pon (1 kg/1,5 kg)
Menyoroti:

HART rosemount 1066 transmitter

,

PV SV Single Channel Transmitter

,

1066-P-HT-73

Rosemount 1066 Single Channel Transmitter 1066-P-HT-73
Product Overview

The Rosemount 1066 Single Channel Transmitter supports continuous measurement of one liquid analytical input - pH sensor, conductivity sensor, chlorine sensor, dissolved oxygen sensor or ozone sensor. The design supports easy internal access and wiring connections. The large display provides excellent visibility for live measurements and displayed parameters, with process values always visible during programming and calibration.

Technical Specifications
Attribute Value
Power Supply Supply voltage at the transmitter terminals should be at least 12.7Vdc. Power supply voltage should cover the voltage drop on the cable plus the external load resistor required for HART® communications (250 Ω)
Communication Protocol HART™ Communications & diagnostics: PV, SV, TV, and 4V assignable, temperature
Diagnostics PV, SV, TV, and 4V assignable
Input One sensor input
Measurement Type Measures pH levels, conductivity levels, chlorine concentration, dissolved oxygen concentration and ozone concentration with compatible sensors
Weight 2 lbs/3 lbs (1 kg/1.5 kg)
Key Features
  • Fast and easy installation using Quick Start programming
  • Intrinsically Safe FM, CSA, and ATEX/IECEx Hazardous Location Approvals
  • Visibility of process parameters through HART® or FOUNDATION™ Fieldbus digital communications
  • Seamless integration with PLCs and DCSs via HART® or FOUNDATION™ Fieldbus communication options
Compatible Part Numbers
2002011 9200273 9210012 9210013 9210014 00390-7101-0001 11275-01 12707-00 23242-02 23554-00 23555-00 23820-00 23820-01 24091-00 24281-00 24281-01 24281-02 24281-03 24281-04 24281-05 24281-06 24281-07 24281-08 24479-00 33342-00 33343-00 33893-00 33894-00 33898-00 34059-00 R508-8OZ