Ana sayfa ÜrünlerEmerson Rosemount Verici

Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3

Ben sohbet şimdi

Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3

Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3
Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3 Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3 Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3

Büyük resim :  Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3

Ürün ayrıntıları:
Menşe yeri: Meksika
Marka adı: Rosemount
Sertifika: CE
Model numarası: 1066-P-HT-73
Ödeme & teslimat koşulları:
Min sipariş miktarı: 1 adet
Fiyat: Pazarlık edilebilir
Ambalaj bilgileri: Standart karton paketleme
Teslim süresi: istek üzerine
Ödeme koşulları: T/T
Yetenek temini: Ayda 100 adet
İletişim Şimdi sohbet et.

Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3

Açıklama
Güç Kaynağı: Verici terminallerindeki besleme voltajı en az 12,7Vdc olmalıdır. Güç kaynağı voltajı, kablodaki vol İletişim protokolü: HART™ İletişim ve teşhis: PV, SV, TV ve 4V atanabilir, sıcaklık
Teşhis: PV, SV, TV ve 4V atanabilir Giriş: Bir sensör girişi
Ölçüm türü: Uyumlu sensörlerle pH seviyelerini, iletkenlik seviyelerini, klor konsantrasyonunu, çözünmüş oksijen Ağırlık: R2 lbs/3 lbs (1 kg/1,5 kg)
Vurgulamak:

HART rosemount 1066 transmitter

,

PV SV Single Channel Transmitter

,

1066-P-HT-73

Rosemount 1066 Single Channel Transmitter 1066-P-HT-73
Product Overview

The Rosemount 1066 Single Channel Transmitter supports continuous measurement of one liquid analytical input - pH sensor, conductivity sensor, chlorine sensor, dissolved oxygen sensor or ozone sensor. The design supports easy internal access and wiring connections. The large display provides excellent visibility for live measurements and displayed parameters, with process values always visible during programming and calibration.

Technical Specifications
Attribute Value
Power Supply Supply voltage at the transmitter terminals should be at least 12.7Vdc. Power supply voltage should cover the voltage drop on the cable plus the external load resistor required for HART® communications (250 Ω)
Communication Protocol HART™ Communications & diagnostics: PV, SV, TV, and 4V assignable, temperature
Diagnostics PV, SV, TV, and 4V assignable
Input One sensor input
Measurement Type Measures pH levels, conductivity levels, chlorine concentration, dissolved oxygen concentration and ozone concentration with compatible sensors
Weight 2 lbs/3 lbs (1 kg/1.5 kg)
Key Features
  • Fast and easy installation using Quick Start programming
  • Intrinsically Safe FM, CSA, and ATEX/IECEx Hazardous Location Approvals
  • Visibility of process parameters through HART® or FOUNDATION™ Fieldbus digital communications
  • Seamless integration with PLCs and DCSs via HART® or FOUNDATION™ Fieldbus communication options
Compatible Part Numbers
2002011 9200273 9210012 9210013 9210014 00390-7101-0001 11275-01 12707-00 23242-02 23554-00 23555-00 23820-00 23820-01 24091-00 24281-00 24281-01 24281-02 24281-03 24281-04 24281-05 24281-06 24281-07 24281-08 24479-00 33342-00 33343-00 33893-00 33894-00 33898-00 34059-00 R508-8OZ
Rosemount 1066 Single Channel Transmitter for pH Conductivity DO Cl O3 0

İletişim bilgileri
SC Automation Limited

İlgili kişi: Ms. Joy chen

Tel: +8615012673027

Faks: 86--15012673027

Sorgunuzu doğrudan bize gönderin (0 / 3000)

Diğer ürünler