خانه محصولاتmtl موانع ایمنی

HART MTL4541 Safety Barrier Repeater Power Supply for Hazardous Areas

چت IM آنلاین در حال حاضر

HART MTL4541 Safety Barrier Repeater Power Supply for Hazardous Areas

HART MTL4541 Safety Barrier Repeater Power Supply for Hazardous Areas
HART MTL4541 Safety Barrier Repeater Power Supply for Hazardous Areas HART MTL4541 Safety Barrier Repeater Power Supply for Hazardous Areas HART MTL4541 Safety Barrier Repeater Power Supply for Hazardous Areas HART MTL4541 Safety Barrier Repeater Power Supply for Hazardous Areas HART MTL4541 Safety Barrier Repeater Power Supply for Hazardous Areas

تصویر بزرگ :  HART MTL4541 Safety Barrier Repeater Power Supply for Hazardous Areas

جزئیات محصول:
محل منبع: ایالات متحده آمریکا
نام تجاری: MTL
گواهی: CE
شماره مدل: MTL4541
پرداخت:
مقدار حداقل تعداد سفارش: 1 قطعه
قیمت: قابل مذاکره
جزئیات بسته بندی: بسته بندی کارتن استاندارد
زمان تحویل: در صورت درخواست
شرایط پرداخت: T/T
قابلیت ارائه: 100 قطعه در هر ماه
مخاطب حالا صحبت کن

HART MTL4541 Safety Barrier Repeater Power Supply for Hazardous Areas

شرح
تعداد کانال ها: یکی محل انتقال: منطقه 0، IIC، T4 ✓6 منطقه خطرناک اگر به درستی گواهی داده شده باشد Div. 1، گروه A محل خطرناک
موج دار شدن مدار در ناحیه امن: <50µA پیک به اوج حرکت دما: <0.8µA/°C
ارتباطات پشتیبانی می شود: HART (فقط ترمینال های 1 و 2) نشانگر LED: سبز: نشانگر قدرت
برجسته کردن:

HART MTL Safety Barrier,MTL4541 MTL Safety Barrier,repeater power supply USA

,

MTL4541 MTL Safety Barrier

,

repeater power supply USA

HART MTL4541 MTL Safety Barrier Repeater Power Supply
Product Overview

The MTLx541 provides a fully-floating DC supply for energizing a conventional 2- or 3-wire 4/20mA transmitter located in a hazardous area, while repeating the current in another floating circuit to drive a safe-area load. For HART 2-wire transmitters, the unit enables bi-directional communication signals superimposed on the 4/20mA loop current.

Key Features
  • Single-channel design for reliable operation
  • Supports HART communication (terminals 1 & 2 only)
  • Green LED power indicator for clear status monitoring
  • Safe-area circuit ripple < 50µA peak-to-peak
  • Low temperature drift < 0.8µA/°C
  • Suitable for Zone 0, IIC, T4-6 hazardous areas when certified
Technical Specifications
Parameter Specification
Number of channels One
Hazardous area classification Zone 0, IIC, T4-6 (when certified)
Div. 1, Group A
Safe-area output Signal range: 4 to 20mA
Under/over-range: 0 to 24mA
Load resistance (MTLx541): 0-360Ω @ 24mA, 0-450Ω @ 20mA
Transfer accuracy at 20°C Better than 15µA
Response time Settles within 10% of final value in 50µs
Power consumption 51mA at 24V (with 20mA signal)
Power dissipation MTLx541: 0.7W @ 24V dc
MTLx541S: 1.0W @ 24V dc
Safety Information

Terminals 2 to 1 and 3: Uo =28V, Io =93mA, Po =651mW, Um = 253V rms or dc. Terminals 1 to 3: Simple apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected without further certification into any IS loop with an open-circuit voltage <28V.

Related Part Numbers
HCU16 MTL5521 MTL4546Y MTL7761PAC HCU3700 MTL5522 MTL4549Y MTL7765AC HM64RIB20-1.0 MTL5531 MTL4573 MTL7787+ HM64RIB20-1.5 MTL5532 MTL4575 MTL7787P+ HMM64 MTL5541 MTL4646Y MTLCPS16 HMRIB16-1.0 MTL5541S MTL4850 NJ5-18GK-N HMS64 MTL5544 MTL4851 SD150X HTP-SC32 MTL5544D MTL4852 SD32 MTL4044D MTL5546 MTL5018 SD32X MTL4511 MTL5546Y MTL5032 SDRTD MTL4516 MTL5561 MTL5042 SLP32D MTL4516C MTL5573 MTL5044 TP48-3-I-NDI MTL4521 MTL5575 MTL5049 TP48-3-N-NDI MTL4541 MTL5582B MTL5511 TP48-4-I-NDI PCL45USB MTL7728+ MTL5514D TP48-4-N-NDI MTL4544 MTL7756AC MTL5516 TP48-N-NDI MTL4544D MTL7760AC MTL5516C ZB24571
HART MTL4541 Safety Barrier Repeater Power Supply for Hazardous Areas 0

اطلاعات تماس
SC Automation Limited

تماس با شخص: Ms. Joy chen

تلفن: +8615012673027

فکس: 86--15012673027

ارسال درخواست خود را به طور مستقیم به ما (0 / 3000)

سایر محصولات