Szczegóły Produktu:
Kontakt
Rozmawiaj teraz
|
| Prąd upływowy: | < 3 µA przy -20 ... 85 °C (-4 ... 185 °F) | Etykietowanie: | miejsce do etykietowania z przodu |
|---|---|---|---|
| Poziom integralności bezpieczeństwa (SIL): | SIL 3 | Stopień ochrony: | IEC 60529:2001 |
| Podłączenie zasilania: | poprzez 14-kanałowy kabel płaski z mastera KFD2-HMM-16 | Opór wyjściowy: | 100 Ω lub mniej, sprzężenie pojemnościowe |
| Temperatura otoczenia: | -20 ... 65 °C (-4 ... 149 °F) | Wymiary: | 20 x 93 x 115 mm (0,8 x 3,7 x 4,5 cala) (szer. x wys. x gł.), obudowa typu B1 |
| Podkreślić: | SIL 3 P+F Sensors,SIL 3 P+F hart multiplexer,p&f hart multiplexer KFD0-HMS-16 |
||
| Attribute | Value |
|---|---|
| Leakage current | < 3 µA at -20 ... 85 °C (-4 ... 185 °F) |
| Labeling | Space for labeling at the front |
| Safety Integrity Level (SIL) | SIL 3 |
| Degree of protection | IEC 60529:2001 |
| Supply Connection | Via 14-channel flat cable form master KFD2-HMM-16 |
| Output resistance | 100 Ω or smaller, capacitive coupling |
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) |
| Dimensions | 20 x 93 x 115 mm (0.8 x 3.7 x 4.5 inch) (W x H x D), housing type B1 |
| Safety Integrity Level (SIL) | SIL 3 |
| Connection | Via 14-channel flat cable form master KFD2-HMM-16 |
| Conformity | HART field device input (revision 5 to 7) |
| Connection | 26-pin flat cable for analog connections 14-pin flat cable for master-slave connection between KFD2-HMM-16 and KFD0-HMS-16 |
| Leakage current | < 3 µA at -20 ... 85 °C (-4 ... 185 °F) |
| Terminating resistor | External 230 ... 500 Ω standard (up to 1000 Ω possible) |
| Output voltage | ≥ 400 mV ss (with the terminator resistance specified above) |
| Output resistance | 100 Ω or smaller, capacitive coupling |
| Input impedance | According to HART specification |
| Input voltage range | 0.08 ... 4 V ss; typ. ± 5.2 V as local reference |
| Labeling | Space for labeling at the front |
| Electromagnetic compatibility | Directive 2014/30/EU EN 61326-1:2013 (industrial locations) |
| Degree of protection | IEC 60529:2001 |
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) |
| Degree of protection | IP20 |
| Mass | Approx. 100 g |
| Dimensions | 20 x 93 x 115 mm (0.8 x 3.7 x 4.5 inch) (W x H x D), housing type B1 |
| Mounting | On 35 mm DIN mounting rail according to EN 60715:2001 |
| Certificate | PF 07 CERT 1143 X |
| Marking | |
| Directive conformity | Directive 2014/34/EU EN 60079-0:2012+A11:2013 EN 60079-15:2010 |
Osoba kontaktowa: Ms. Joy chen
Tel: +8615012673027
Faks: 86--15012673027