Home ProductsP+F Sensors

SIL 3 P+F Sensors HART Multiplexer Slave KFD0-HMS-16

I'm Online Chat Now

SIL 3 P+F Sensors HART Multiplexer Slave KFD0-HMS-16

SIL 3 P+F Sensors HART Multiplexer Slave KFD0-HMS-16
SIL 3 P+F Sensors HART Multiplexer Slave KFD0-HMS-16 SIL 3 P+F Sensors HART Multiplexer Slave KFD0-HMS-16

Large Image :  SIL 3 P+F Sensors HART Multiplexer Slave KFD0-HMS-16

Product Details:
Place of Origin: Germany
Brand Name: P+F
Certification: PF 07 CERT 1143 X
Model Number: KFD0-HMS-16
Payment & Shipping Terms:
Minimum Order Quantity: 1 piece
Price: negotiable
Packaging Details: standard carton packing
Delivery Time: on request
Payment Terms: T/T
Supply Ability: 100pcs per month
Contact Now Chat Now

SIL 3 P+F Sensors HART Multiplexer Slave KFD0-HMS-16

Description
Leakage Current: < 3 µA At -20 ... 85 °C (-4 ... 185 °F) Labeling: Space For Labeling At The Front
Safety Integrity Level (SIL): SIL 3 Degree Of Protection: IEC 60529:2001
Supply Connection: Via 14-channel Flat Cable Form Master KFD2-HMM-16 Output Resistance: 100 Ω Or Smaller, Capacitive Coupling
Ambient Temperature: -20 ... 65 °C (-4 ... 149 °F) Dimensions: 20 X 93 X 115 Mm (0.8 X 3.7 X 4.5 Inch) (W X H X D) , Housing Type B1
Highlight:

SIL 3 P+F Sensors

,

SIL 3 P+F hart multiplexer

,

p&f hart multiplexer KFD0-HMS-16

SIL 3 HART Multiplexer P+F Sensors Slave KFD0-HMS-16
Product Specifications
Attribute Value
Leakage current < 3 µA at -20 ... 85 °C (-4 ... 185 °F)
Labeling Space for labeling at the front
Safety Integrity Level (SIL) SIL 3
Degree of protection IEC 60529:2001
Supply Connection Via 14-channel flat cable form master KFD2-HMM-16
Output resistance 100 Ω or smaller, capacitive coupling
Ambient temperature -20 ... 65 °C (-4 ... 149 °F)
Dimensions 20 x 93 x 115 mm (0.8 x 3.7 x 4.5 inch) (W x H x D), housing type B1
Product Description
Multiplexer Slave KFD0-HMS-16
  • 16-channel HART field device input (revision 5 to 7)
  • No external power required
  • Used with HART Multiplexer Master KFD2-HMM-16
  • Up to SIL 3 according to IEC/EN 61508
Technical Data
Functional Safety
Safety Integrity Level (SIL) SIL 3
Supply
Connection Via 14-channel flat cable form master KFD2-HMM-16
HART Signal Channels
Conformity HART field device input (revision 5 to 7)
Connection 26-pin flat cable for analog connections
14-pin flat cable for master-slave connection between KFD2-HMM-16 and KFD0-HMS-16
Leakage current < 3 µA at -20 ... 85 °C (-4 ... 185 °F)
Terminating resistor External 230 ... 500 Ω standard (up to 1000 Ω possible)
Output voltage ≥ 400 mV ss (with the terminator resistance specified above)
Output resistance 100 Ω or smaller, capacitive coupling
Input impedance According to HART specification
Input voltage range 0.08 ... 4 V ss; typ. ± 5.2 V as local reference
Indicators/Settings
Labeling Space for labeling at the front
Directive Conformity
Electromagnetic compatibility Directive 2014/30/EU
EN 61326-1:2013 (industrial locations)
Conformity
Degree of protection IEC 60529:2001
Ambient Conditions
Ambient temperature -20 ... 65 °C (-4 ... 149 °F)
Mechanical Specifications
Degree of protection IP20
Mass Approx. 100 g
Dimensions 20 x 93 x 115 mm (0.8 x 3.7 x 4.5 inch) (W x H x D), housing type B1
Mounting On 35 mm DIN mounting rail according to EN 60715:2001
Hazardous Area Certification
Certificate PF 07 CERT 1143 X
Marking SIL 3 P+F Sensors HART Multiplexer Slave KFD0-HMS-16 0 II 3G Ex nA IIC T4 Gc
Directive conformity Directive 2014/34/EU
EN 60079-0:2012+A11:2013
EN 60079-15:2010
Product Images
SIL 3 P+F Sensors HART Multiplexer Slave KFD0-HMS-16 1 SIL 3 P+F Sensors HART Multiplexer Slave KFD0-HMS-16 2 SIL 3 P+F Sensors HART Multiplexer Slave KFD0-HMS-16 3
Related Models

Contact Details
SC Automation Limited

Contact Person: Ms. Joy chen

Tel: +8615012673027

Fax: 86--15012673027

Send your inquiry directly to us (0 / 3000)