Home ProductsYOKOGAWA Transmitter

Yokogawa ALR121-S00 RS422 RS485 Transmitter Module

I'm Online Chat Now

Yokogawa ALR121-S00 RS422 RS485 Transmitter Module

Yokogawa ALR121-S00 RS422 RS485 Transmitter Module
Yokogawa ALR121-S00 RS422 RS485 Transmitter Module Yokogawa ALR121-S00 RS422 RS485 Transmitter Module Yokogawa ALR121-S00 RS422 RS485 Transmitter Module

Large Image :  Yokogawa ALR121-S00 RS422 RS485 Transmitter Module

Product Details:
Place of Origin: Indonesia
Brand Name: YOKOGAWA
Certification: CE
Model Number: ALR121-S00
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Price: negotiable
Packaging Details: standard carton packing
Delivery Time: on request
Payment Terms: T/T
Supply Ability: 100pcs per month
Contact Now Chat Now

Yokogawa ALR121-S00 RS422 RS485 Transmitter Module

Description
Manufacturers: Yokogawa Interface: RS-422/RS-485 (4-wire System)
Connection Method: Point-to-point (RS-422) Multipoint (RS-485) Communication Function: Half-duplex
Synchronization Method: Start-stop Synchronization Transmission Distance: Maximum 1200 M (total Extended Length)
Current Consumption: 0.5 A Weight: Approx. 0.34 Kg
Highlight:

RS422 YOKOGAWA Transmitter

,

RS485 YOKOGAWA Transmitter

,

ALR121-S00

RS422 RS485 YOKOGAWA Transmitter Module ALR121-S00
Product Specifications
Manufacturers Yokogawa
Interface RS-422/RS-485 (4-wire system)
Connection method Point-to-point (RS-422) Multipoint (RS-485)
Communication function Half-duplex
Synchronization method Start-stop synchronization
Transmission distance Maximum 1200 m (total extended length)
Current consumption 0.5 A
Weight Approx. 0.34 kg
Product Description
The YOKOGAWA RS422/RS485 Module ALR121-S00 is part of the ALR111 and ALR121 Serial Communication Modules series designed for use with safety control stations (SCS) to perform Modbus communication.
Key Features
  • Enables data setting and reference in SCS via Modbus master from separate systems
  • Allows subsystem data handling from sequencers using SCS's subsystem communication function
  • Compatible with safety control units and safety node units
  • Interference-free design that doesn't affect safety loops
Technical Specifications
Item Specifications
Model ALR121
Interface RS-422/RS-485 (4-wire system)
Connection method Point-to-point (RS-422) Multipoint (RS-485)
Communication function Half-duplex
Synchronization method Start-stop synchronization
Transmission speed 1200/2400/4800/9600/19200/38400 bps
Transmission code binary
Character length 8 bits (Fixed to 8 bit on the Modbus slave communication function and the subsystem communication function)
Stop bit length 1/2 bits (Fixed to 1 bit on the subsystem communication function)
Parity check None/even/odd
Lag time after data transmission 1 ms
Transmission distance Maximum 1200 m (total extended length)
Installation method Mounted on S2SC70, SSC60, SSC50, SSC57, or SNB10D
I/O wiring Cable with 3-pair shield, AKB161, or AKB162
Wiring connection Clamped with terminal block's M4 screws (5 poles × 2 ports)
Communication function Modbus slave communication function, subsystem communication function
Current consumption 0.5 A
Weight Approx. 0.34 kg
Note: A unit of SCS is capable of handling multiple communication functions; however, different types of communication functions cannot be simultaneously performed on a serial communication module. Both ports must have identical communication functions.
Related Part Numbers
AAI135-S00
AAI143-H00
AAI143-H53
AAI143-S50
AAI543-S00
AAI835-H00
AAI835-H00/K4A00
AAI835-S00
AAI835-S50
AAM51
AAT145-S00
ACCC01
ACM12
ADM11c
ADM12
ADM52C
ADV151-P00
ADV151-P50/D5A00
ADV151-P63
ADV151-P63/D5A00
ADV159-P00
ADV551
ADV551-P50/D5A00
ADV551-P63
AED5D-00
AIP601
AIP826
AIP827-2
AIP830-101
AIP830-101-EIM-VESA
AKB331-M020
ALE111-S50
ALE111-S51
ALR121-S00
AMN33
ATD5A-00
ATK4A-00
AX01C-C010-CH
AX01C-C015/CH
Yokogawa ALR121-S00 RS422 RS485 Transmitter Module 0