MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

Im Online Czat teraz

MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface
MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

Duży Obraz :  MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

Szczegóły Produktu:
Miejsce pochodzenia: ANGLIA
Nazwa handlowa: MTL
Orzecznictwo: CE
Numer modelu: MTL4514
Zapłata:
Minimalne zamówienie: 1 szt
Cena: Zbywalny
Szczegóły pakowania: Standardowe pakowanie kartonu
Czas dostawy: na żądanie
Zasady płatności: T/T
Możliwość Supply: 100pcs miesięcznie
Kontakt Rozmawiaj teraz

MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

Opis
Liczba kanałów: Jeden Lokalizacja przełącznika: Strefa 0, IIC, T6 Divous Area Div.1, grupa A, Lokalizacja niebezpieczna
Lokalizacja czujnika zbliżeniowego: Strefa 0, IIC, obszar niebezpieczny T4–6, jeśli posiada odpowiedni certyfikat, dział 1, grupa A, lok Dane wejściowe dotyczące obszarów niebezpiecznych: Wejścia zgodne z BS EN60947–5–6: 2001 dla detektorów bliskości (Namur)
Napięcie stosowane do czujnika: 7 do 9 V prądu stałego od 1kΩ ±10% Wyjście z strefy bezpieczeństwa: dwa jednobiegunowe przekaźniki ze stykiem normalnie otwartym
Podkreślić:

MTL5514D Switch/Proximity Detector Interface

,

MTL4514D Switch/Proximity Detector Interface

,

Harsh Environments Switch/Proximity Detector Interface

MTL4514D – MTL5514D Switch/Proximity Detector Interface for Harsh Environments
Product Specifications
Attribute Value
Number of channels One
Location of switch Zone 0, IIC, T6 hazardous area Div.1, Group A, hazardous location
Location of proximity detector Zone 0, IIC, T4–6 hazardous area, if suitably certified Div.1, Group A, hazardous location
Hazardous–area inputs Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)
Voltage applied to sensor 7 to 9V dc from 1kΩ ±10%
Safe-area output Two, single pole relays with normally-open contact
Product Description

The MTLx514D enables two safe-area loads to be controlled, through relays, by a proximity detector or switch located in a hazardous area. When selected, open or short circuit conditions in the field wiring are detected by the line fault detect (LFD) facility and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.

Relay Characteristics
Specification MTL4514D MTL5514D
Response time 10ms maximum 10ms maximum
Contact rating (Safe Area) 10W, 0.5A, 35V dc 250V ac, 2A, cosØ >0.7, 40V dc, 2A, resistive load
Contact rating (Zone 2) 10W, 0.5A, 35V dc 35V, 2A, 100VA
MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface 0