MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

Tôi trò chuyện trực tuyến bây giờ

MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface
MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

Hình ảnh lớn :  MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

Thông tin chi tiết sản phẩm:
Nguồn gốc: ANH
Hàng hiệu: MTL
Chứng nhận: CE
Số mô hình: MTL4514
Thanh toán:
Số lượng đặt hàng tối thiểu: 1 cái
Giá bán: Có thể thương lượng
chi tiết đóng gói: Đóng gói carton tiêu chuẩn
Thời gian giao hàng: theo yêu cầu
Điều khoản thanh toán: T/T
Khả năng cung cấp: 100pc mỗi tháng
Tiếp xúc Chat ngay bây giờ

MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

Sự miêu tả
Số lượng kênh: Một Vị trí công tắc: Vùng 0, IIC, khu vực nguy hiểm T6 Div.1, Nhóm A, Vị trí nguy hiểm
Vị trí của máy dò tiệm cận: Vùng 0, IIC, T4–6 khu vực nguy hiểm, nếu được chứng nhận phù hợp Phân khu 1, Nhóm A, địa điểm nguy h Đầu vào khu vực nguy hiểm: Đầu vào phù hợp với BS EN60947 Từ5
Điện áp áp dụng cho cảm biến: 7 đến 9V dc từ 1kΩ ±10% Khả năng đầu ra khu vực an toàn: hai rơle một cực có tiếp điểm thường mở
Làm nổi bật:

MTL5514D Switch/Proximity Detector Interface

,

MTL4514D Switch/Proximity Detector Interface

,

Harsh Environments Switch/Proximity Detector Interface

MTL4514D – MTL5514D Switch/Proximity Detector Interface for Harsh Environments
Product Specifications
Attribute Value
Number of channels One
Location of switch Zone 0, IIC, T6 hazardous area Div.1, Group A, hazardous location
Location of proximity detector Zone 0, IIC, T4–6 hazardous area, if suitably certified Div.1, Group A, hazardous location
Hazardous–area inputs Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)
Voltage applied to sensor 7 to 9V dc from 1kΩ ±10%
Safe-area output Two, single pole relays with normally-open contact
Product Description

The MTLx514D enables two safe-area loads to be controlled, through relays, by a proximity detector or switch located in a hazardous area. When selected, open or short circuit conditions in the field wiring are detected by the line fault detect (LFD) facility and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.

Relay Characteristics
Specification MTL4514D MTL5514D
Response time 10ms maximum 10ms maximum
Contact rating (Safe Area) 10W, 0.5A, 35V dc 250V ac, 2A, cosØ >0.7, 40V dc, 2A, resistive load
Contact rating (Zone 2) 10W, 0.5A, 35V dc 35V, 2A, 100VA
MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface 0