Rumah ProdukMtl penghalang keamanan

MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

I 'm Online Chat Now

MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface
MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

Gambar besar :  MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

Detail produk:
Tempat asal: INGGRIS
Nama merek: MTL
Sertifikasi: CE
Nomor model: MTL4514
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1 buah
Harga: Bisa dinegosiasikan
Kemasan rincian: Pengepakan karton standar
Waktu pengiriman: berdasarkan permintaan
Syarat-syarat pembayaran: T/T
Menyediakan kemampuan: 100 pcs per bulan
Kontak Chat Sekarang

MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface

Deskripsi
Jumlah Saluran: Satu Lokasi saklar: Zona 0, IIC, T6 Area Berbahaya Div.1, Grup A, Lokasi Berbahaya
Lokasi detektor kedekatan: Zona 0, IIC, T4–6 area berbahaya, jika disertifikasi sesuai Div.1, Grup A, lokasi berbahaya Masukan area berbahaya: Input yang sesuai dengan BS EN60947–5–6: 2001 Standar untuk Detektor Kedekatan (NAMUR)
Tegangan yang diterapkan pada sensor: 7 sampai 9V DC dari 1kΩ ±10% Output area aman: dua, relai kutub tunggal dengan kontak yang biasanya terbuka
Menyoroti:

MTL5514D Switch/Proximity Detector Interface

,

MTL4514D Switch/Proximity Detector Interface

,

Harsh Environments Switch/Proximity Detector Interface

MTL4514D – MTL5514D Switch/Proximity Detector Interface for Harsh Environments
Product Specifications
Attribute Value
Number of channels One
Location of switch Zone 0, IIC, T6 hazardous area Div.1, Group A, hazardous location
Location of proximity detector Zone 0, IIC, T4–6 hazardous area, if suitably certified Div.1, Group A, hazardous location
Hazardous–area inputs Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)
Voltage applied to sensor 7 to 9V dc from 1kΩ ±10%
Safe-area output Two, single pole relays with normally-open contact
Product Description

The MTLx514D enables two safe-area loads to be controlled, through relays, by a proximity detector or switch located in a hazardous area. When selected, open or short circuit conditions in the field wiring are detected by the line fault detect (LFD) facility and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.

Relay Characteristics
Specification MTL4514D MTL5514D
Response time 10ms maximum 10ms maximum
Contact rating (Safe Area) 10W, 0.5A, 35V dc 250V ac, 2A, cosØ >0.7, 40V dc, 2A, resistive load
Contact rating (Zone 2) 10W, 0.5A, 35V dc 35V, 2A, 100VA
MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface 0