Home ProductsMTL Safety Barrier

MTL5521 Solenoid Alarm Driver 20-35V DC Safety Barrier

I'm Online Chat Now

MTL5521 Solenoid Alarm Driver 20-35V DC Safety Barrier

MTL5521 Solenoid Alarm Driver 20-35V DC Safety Barrier
MTL5521 Solenoid Alarm Driver 20-35V DC Safety Barrier MTL5521 Solenoid Alarm Driver 20-35V DC Safety Barrier MTL5521 Solenoid Alarm Driver 20-35V DC Safety Barrier MTL5521 Solenoid Alarm Driver 20-35V DC Safety Barrier

Large Image :  MTL5521 Solenoid Alarm Driver 20-35V DC Safety Barrier

Product Details:
Place of Origin: USA
Brand Name: MTL
Certification: CE
Model Number: MTL5521
Payment & Shipping Terms:
Minimum Order Quantity: 1 piece
Price: negotiable
Packaging Details: standard carton packing
Delivery Time: on request
Payment Terms: T/T
Supply Ability: 100pcs per month
Contact Now Chat Now

MTL5521 Solenoid Alarm Driver 20-35V DC Safety Barrier

Description
Number Of Channels: One Input Voltage: 20 To 35V Dc
Response Time: Output Within 10% Of Final Value Within 100ms Power Dissipation Within Unit: 1.4W At 24V
LED Indicator: Yellow: Output Status, On When Output Active Maximum Power Dissipation Within Unit: 90mA At 24V
Highlight:

MTL5521

,

MTLx521 ALARM DRIVER

,

ALARM DRIVER CE

MTL5521 MTLx521 SOLENOID ALARM DRIVER CE
Product Specifications
Attribute Value
Number of channels One
Input voltage 20 to 35V dc
Response time Output within 10% of final value within 100ms
Power dissipation within unit 1.4W at 24V
LED indicator Yellow: output status, on when output active
Maximum power dissipation within unit 90mA at 24V
Product Description
MTL5521 SOLENOID/ALARM DRIVER

The MTLx521 and the MTL4521L are loop-powered modules which enable a device located in the hazardous area to be controlled from the safe area. They can drive a certified intrinsically safe low-power load, as well as non-energy-storing simple apparatus such as an LED.

Specification Details
  • Number of channels: One
  • Location of load: Zone 0, IIC, T4-6 hazardous area if suitably certified Div. 1, Group A hazardous location
  • Input voltage: 20 to 35V dc
  • Hazardous-area output (MTLx521): Minimum output voltage: 13.6V at 48mA; Maximum output voltage: 24V from 180Ω; Current limit: 48mA minimum
  • Hazardous-area output (MTL4521L): Minimum output voltage: 11.1V at 48mA; Maximum output voltage: 24V from 232Ω; Current limit: 48mA minimum
  • Output ripple: < 0.5% of maximum output, peak to peak
  • Response time: Output within 10% of final value within 100ms
  • LED indicator: Yellow: output status, on when output active
  • Maximum current consumption: 90mA at 24V
  • Power dissipation within unit: 1.4W at 24V
  • Safety description (MTLx521): Uo =25V Io =147mA Po =0.92W Um = 253V rms or dc
  • Safety description (MTL4521L): Uo = 25V Io = 108mA Po = 0.68W Um = 253V rms or dc
Related Part Numbers
HCU16
MTL5521
MTL4546Y
MTL7761PAC
HCU3700
MTL5522
MTL4549Y
MTL7765AC
HM64RIB20-1.0
MTL5531
MTL4573
MTL7787+
HM64RIB20-1.5
MTL5532
MTL4575
MTL7787P+
HMM64
MTL5541
MTL4646Y
MTLCPS16
HMRIB16-1.0
MTL5541S
MTL4850
NJ5-18GK-N
HMS64
MTL5544
MTL4851
SD150X
HTP-SC32
MTL5544D
MTL4852
SD32
MTL4044D
MTL5546
MTL5018
SD32X
MTL4511
MTL5546Y
MTL5032
SDRTD
MTL4516
MTL5561
MTL5042
SLP32D
MTL4516C
MTL5573
MTL5044
TP48-3-I-NDI
MTL4521
MTL5575
MTL5049
TP48-3-N-NDI
MTL4541
MTL5582B
MTL5511
TP48-4-I-NDI
PCL45USB
MTL7728+
MTL5514D
TP48-4-N-NDI
MTL4544
MTL7756AC
MTL5516
TP48-N-NDI
MTL4544D
MTL7760AC
MTL5516C
ZB24571
MTL5521 Solenoid Alarm Driver 20-35V DC Safety Barrier 0

Contact Details
SC Automation Limited

Contact Person: Ms. Joy chen

Tel: +8615012673027

Fax: 86--15012673027

Send your inquiry directly to us (0 / 3000)