Ana sayfa Ürünlermtl güvenlik bariyeri

MTL5014 NAMUR Proximity Detector Interface for Hazardous Areas

Ben sohbet şimdi

MTL5014 NAMUR Proximity Detector Interface for Hazardous Areas

MTL5014 NAMUR Proximity Detector Interface for Hazardous Areas
MTL5014 NAMUR Proximity Detector Interface for Hazardous Areas MTL5014 NAMUR Proximity Detector Interface for Hazardous Areas MTL5014 NAMUR Proximity Detector Interface for Hazardous Areas MTL5014 NAMUR Proximity Detector Interface for Hazardous Areas

Büyük resim :  MTL5014 NAMUR Proximity Detector Interface for Hazardous Areas

Ürün ayrıntıları:
Menşe yeri: İNGİLTERE
Marka adı: MTL
Sertifika: CE
Model numarası: MTL5014
Ödeme & teslimat koşulları:
Min sipariş miktarı: 1 adet
Fiyat: Pazarlık edilebilir
Ambalaj bilgileri: Standart karton paketleme
Teslim süresi: istek üzerine
Ödeme koşulları: T/T
Yetenek temini: Ayda 100 adet
İletişim Şimdi sohbet et.

MTL5014 NAMUR Proximity Detector Interface for Hazardous Areas

Açıklama
Kanal Sayısı: Bir Anahtarların Konumu: Bölge 0, IIC, T6 tehlikeli alan Böl. 1, Grup A tehlikeli konum
Yakınlık dedektörlerinin konumu: Bölge 0, IIC, T4?? 6 uygun şekilde sertifikalandırılmışsa Div. 1, A grubu tehlikeli yer Güvenli alan çıkışı: Değişim bağlantıları olan iki röle
Tehlikeli giriş: Yakınlık dedektörleri için NAMUR/DIN 19234 standartlarına uygun bir giriş Yakınlık dedektörleri için NAMUR/DIN 19234 standartlarına uygun bir giriş: 1kΩ ±%10'dan 7,0 ila 9,0V
Vurgulamak:

Hazardous Area Switch/Proximity Detector Interface

,

NAMUR Switch/Proximity Detector Interface

,

DIN 19234 Switch/Proximity Detector Interface

MTL5014 Switch/Proximity Detector Interface NAMUR/DIN 19234 Standards for Hazardous Area
Product Attributes
Attribute Value
Number of channels One
Location of switches Zone 0, IIC, T6 hazardous area Div. 1, Group A hazardous location
Location of proximity detectors Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location
Safe-area output Two relays with changeover contacts
Hazardous-area input One input conforming to NAMUR/DIN 19234 standards for proximity detectors
Voltage specification 7.0 to 9.0V from 1kΩ ±10%
Product Description
The MTL5014 enables two safe-area loads to be controlled by a single switch or proximity detector located in the hazardous area. The safe-area interface has two changeover relays: output 1 and output 2. The output 1 relay reflects the status of the input and may be configured to operate in reverse phase. The output 2 relay may be configured either to repeat (slave) the output 1 relay, or to act as a line integrity monitor. A selectable line-fault-detect (LFD) facility enables an open- or short- circuit fault to be detected in the field wiring.
Related Models
MTL5014 NAMUR Proximity Detector Interface for Hazardous Areas 0

İletişim bilgileri
SC Automation Limited

İlgili kişi: Ms. Joy chen

Tel: +8615012673027

Faks: 86--15012673027

Sorgunuzu doğrudan bize gönderin (0 / 3000)