Input:Accepts 1 non-contacting 3300 NSv Proximity Probe and extension cable.
Power:Requires +12 to +35 Vdc input at the transmitter terminal.
4 to 20 mA signal output:4 to 20 mAdc over specified fullscale range in 2-wire configuration.
Band:Bently Nevada
Model:16710-15/16710-30
type:3-conductor shielded 22 AWG
Unthreaded Length Option:0 mm
Overall Case Length Option:60 mm
Total Length Option:1.0 meter (3.3 feet)
Band:Bently Nevada
Model:87143-15
Shielded or not:2-wire shielded 18 AWG
Sensitivity:3.94mV/mm/s (100 mV/in/s) ±5%.
Frequency Response:4.5 Hz to 5 kHz (270 cpm to 300 kcpm) ±3.0 dB. 6.0 Hz to 2.5 kHz (360 cpm to 150 kcpm) ±0.9 dB.
Temperature Sensitivity:-14% to +7.5% typical over the operating temperature range.
Probe Tip Material:Polyphenylene sulfide (PPS)
Probe Case Material:AISI 303 or 304 stainless steel (SST)
Connector Material:Gold-plated brass or goldplated beryllium copper.
Part Number:40113-02
Model Number:Model Number
Manufacturer:Manufacturer
Sensitivity:3.94 mV/mm/s (100 mV/in/s) ±5%.
Frequency Response:3.0 Hz to 900 Hz (180 to 54,000 cpm) ±1.0 dB 1.5 Hz to 1.0 kHz (90 to 60,000 cpm) ±3.0 dB
Temperature Sensitivity:-8% to +5% typical over the operating temperature range
Proximitor Sensor Input:Accepts one non-contacting 3300-series 5 mm, 3300 XL 8 mm Proximity Probe and Extension Cable.
Power:Requires -17.5 Vdc to -26 Vdc when installed with nonincendive circuit connected per installation drawing 140979 at 12 mA maximum consumption, -23 Vdc to -26 Vdc with barriers. Operation at a more positive voltage than -23.5 Vdc can result in reduced linea
Supply Sensitivity:Less than 2 mV change in output voltage per volt change in input voltage.
Sensitivity @ 80 Hz (± 12%):10.2 mV/(m/s2) (100 mV/g)
Mounted Resonant Frequency:>20 kHz (>1200 kcpm)
Size:17.5 mm x 45.7 mm (
3300 XL 8mm Probe:Temperature Range -51°C to +177°C
3300 XL 11mm Probe:Temperature Range -51°C to +177°C
3300 NSv Probe Operating:-34°C to +177°C
Proximitor Sensor Input:Accepts one non-contacting 3300-series 5 mm, 3300 XL 8 mm Proximity Probe and Extension Cable.
Power:Requires -17.5 Vdc to -26 Vdc when installed with nonincendive circuit connected per installation drawing 140979 at 12 mA maximum consumption, -23 Vdc to -26 Vdc with barriers. Operation at a more positive voltage than -23.5 Vdc can result in reduced linea
Supply Sensitivity:Less than 2 mV change in output voltage per volt change in input voltage.