Proximitor Sensor Input:Accepts one non-contacting 3300-series 5 mm, 3300 XL 8 mm Proximity Probe and Extension Cable.
Power:Requires -17.5 Vdc to -26 Vdc when installed with nonincendive circuit connected per installation drawing 140979 at 12 mA maximum consumption, -23 Vdc to -26 Vdc with barriers. Operation at a more positive voltage than -23.5 Vdc can result in reduced linea
Supply Sensitivity:Less than 2 mV change in output voltage per volt change in input voltage.
Electric:95-125 Vac, 50/60 Hz, 1A minimum 190-250 Vac, 50/60 Hz, 1A minimum
Air:90 psi (6.2 bar) maximum
Vibration Amplitude Range::50 μm to 254 μm (2 to 10 mils) peak-to-peak.
Sensitivity:Sensitivity
Frequency Response:4.5 to 2,000 Hz (270 to 120,000 cpm) ±3.0 dB, 6.0 to 1,000 Hz (360 to 60,000 cpm) ±0.9 dB.
Weight:156 g (5.5 oz), typical
Probe Tip Material:Polyphenylene sulfide (PPS)
Probe Case Material:AISI 304 stainless steel (SST).
Proximitor Sensor Material:A380 aluminum
Proximitor Sensor Input:Accepts one non-contacting 3300-series 5 mm, 3300 XL 8 mm Proximity Probe and Extension Cable.
Supply Sensitivity:Less than 2 mV change in output voltage per volt change in input voltage.
Output Resistance:50 Ω
Length:6m(19.7inch)
Extension cable dc resistance:Center conductor: 0.220 Ω/m (0.067 Ω/ft) Shield: 0.066 Ω/m (0.020 Ω/ft)
Extension cable capacitance:69.9 pF/m (21.3 pF/ft) typical
Cable exit:Top exit sensor
Sensitivity:100 mV/g
Accel range:± 80 g
High Pressure Side Thread Size:1/2-14 NPT
Cable Grommet and Washer 0 0 Solid grommet (:Grommet will accommodate up to 4 cables. One hole is punched and three are partially predrilled.
Low Pressure Side Thread Size:1/2-14 NPT
Manufacturer:Bently Nevada
Part No:330980-71-CN
Length:7.0 meters (23.0 feet)
Weight:131 g (4.62 oz), typical
Diameter:25.4 mm (1.00 in)
Height:66.0 mm (2.60 in)
Proximitor Sensor Material:A380 aluminum
Sliding Bracket Material:Anodized aluminum and stainless steel
System Length:5 or 9 metres including extension cable
Sensitivity:20 mV/mm/s (500 mV/in/s), ±5% when properly terminated and oriented at the angle of calibration.
Calibration Load:10 kΩ Terminal "A" to "B" Output taken across pins "A" and "B"
Sensitivity Temperature Coefficient:0.2%/°C